TUFLOW Message 2340: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
 
(2 intermediate revisions by the same user not shown)
Line 5: Line 5:
|message_desc=The file being read into the 2D model (.tbc file) using the <tt><font color="blue">Read GIS BC </font><font color="red">== </font></tt> does not appear to be a 2d_bc format file. This has less than the required 8 attributes for this layer.<br>
|message_desc=The file being read into the 2D model (.tbc file) using the <tt><font color="blue">Read GIS BC </font><font color="red">== </font></tt> does not appear to be a 2d_bc format file. This has less than the required 8 attributes for this layer.<br>
The primary reason for this to occur is that a 1d boundary layer (1d_bc) file is being read into the .tbc file and not into the 1d domain (.ecf file). If the filename contains the text '''1d_bc''' the additional output <tt>File appears to be a 1d_bc file and not a 2d_bc </tt> is also included in the output message.<br>
The primary reason for this to occur is that a 1d boundary layer (1d_bc) file is being read into the .tbc file and not into the 1d domain (.ecf file). If the filename contains the text '''1d_bc''' the additional output <tt>File appears to be a 1d_bc file and not a 2d_bc </tt> is also included in the output message.<br>
Prior to the 2016 version of TUFLOW the accidental reading of a 1d_bc layer into the 2D boundary control file .tbc could cause an [[TUFLOW_Message_2056 | ERROR 2056]] to occur.
Prior to the 2016 version of TUFLOW the accidental reading of a 1d_bc layer into the 2D boundary control file .tbc could cause an <u>[[TUFLOW_Message_2056 | ERROR 2056]]</u> to occur.
|suggestions=Check that the 2d_bc file has the correct attributes and if a 1D boundary is being specified, please read this into the 1D control file (.ecf) or within a Start 1D Domain --> End 1D Domain block of commands in the .tcf.<br>
|suggestions=Check that the 2d_bc file has the correct attributes and if a 1D boundary is being specified, please read this into the 1D control file (.ecf) or within a Start 1D Domain --> End 1D Domain block of commands in the .tcf.<br>
Check that other type of layer, such as 2d_sa isn't read with the <tt><font color="blue">Read GIS BC </font><font color="red">== </font></tt> command.
Check that other type of layer, such as 2d_sa isn't read with the <tt><font color="blue">Read GIS BC </font><font color="red">== </font></tt> command.

|discussion_page=* [[Talk:TUFLOW Message 2340|Discuss Message 2340]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_2336|Message 2336]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2343|Message 2343]]
}}
}}

Latest revision as of 15:09, 7 February 2023

TUFLOW Message
ERROR 2340 - Less than 8 attributes for 2d_bc file: <filename>

Alternate Message
NA

Message Type
ERROR

Description
The file being read into the 2D model (.tbc file) using the Read GIS BC == does not appear to be a 2d_bc format file. This has less than the required 8 attributes for this layer.
The primary reason for this to occur is that a 1d boundary layer (1d_bc) file is being read into the .tbc file and not into the 1d domain (.ecf file). If the filename contains the text 1d_bc the additional output File appears to be a 1d_bc file and not a 2d_bc is also included in the output message.
Prior to the 2016 version of TUFLOW the accidental reading of a 1d_bc layer into the 2D boundary control file .tbc could cause an ERROR 2056 to occur.

Suggestions
Check that the 2d_bc file has the correct attributes and if a 1D boundary is being specified, please read this into the 1D control file (.ecf) or within a Start 1D Domain --> End 1D Domain block of commands in the .tcf.
Check that other type of layer, such as 2d_sa isn't read with the Read GIS BC == command.


Up
2xxx Messages