TUFLOW Message 2061: Difference between revisions

Content deleted Content added
No edit summary
No edit summary
 
(6 intermediate revisions by 3 users not shown)
Line 4:
|type=[[ERROR]]
|message_desc=Could not find a connection (CN object) snapped to the end of the 1D/2D interface (HX) line. Check that any connection object is snapped; add a connection to the end of the 1D/2D interface; or edit the 1D/2D interface line. 1D/2D interface lines based on the HX type must have as a minimum a connection at each of its ends, otherwise it is not clear how to transfer the water level gradient from the 1D domain.
|suggestions=The messages.mif or messages_P.shp file should contain the location that this error is occurring. Zoom into the HX line and check that the connection line is snapped to the end vertices of the line. This line can have CN connections snapped to intermediate vertices, but <u>'''must '''</u> have a CN line snapped to each end.
 
|discussion_page=* [[Talk:TUFLOW Message 2061|Discuss Message 2061]]
'''Please note:''' If the model is a Flood Modeller-TUFLOW (FM-TUFLOW) model and you are trying to run as a TUFLOW only model, this is a common error message as TUFLOW cannot find the external 1D nodes which are linked through the CN line(s) to the HX line(s). For more details on running a FM-TUFLOW model please visit the WIKI page below: [https://wiki.tuflow.com/Running_linked_Flood_Modeller_-_TUFLOW_Models Running linked Flood modeller - TUFLOW Models]
|link3=''
 
|link4=''
|prelink=[[TUFLOW_Message_2060|Message 2060]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2062|Message 2062]]
}}