TUFLOW Message 2016: Difference between revisions

Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=Unrecognisable 2D connection specified for pit or manhole. |suggestions=???? |discussion_page=* [[Talk:TUFLOW Message 2016|Dis...'
 
No edit summary
 
(5 intermediate revisions by 3 users not shown)
Line 1:
{{TUFLOW_Message
|tuflow_message=ERROR 2016 - Unrecognisable 2D connection specified for pit or manhole.
|tuflow_message=????
|alt_msg=NA
|type=[[ERROR]]
|message_desc=Unrecognisable 2D connection specified for pit or manhole.
|suggestions=The Conn_2D attribute in the 1d_nwk can be used to create a 2D connection. Valid options are:
|suggestions=????
* SX
|discussion_page=* [[Talk:TUFLOW Message 2016|Discuss Message 2016]]
* SXZ
|link3=''
* SXL
|link4=''
* SXG
|prelink=[[TUFLOW_Message_2015|Message 2015]]
* SXS
|nextlink=[[TUFLOW_Message_2017|Message 2017]]
For more information on these, refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u>.<br>
<br>
If you are using th GPU virtual pipes feature, this error may occur if you have spcified the 'Width' or 'Conn_No' as Zero
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
}}