TUFLOW Message 2041: Difference between revisions

Content deleted Content added
No edit summary
No edit summary
 
(9 intermediate revisions by 5 users not shown)
Line 3:
|alt_msg=ERROR 2041 - Too many HS tables. <br> ERROR 2041 - Too many HT tables. <br> ERROR 2041 - Too many HX tables. <br> ERROR 2041 - Too many QC tables. <br> ERROR 2041 - Too many QT tables. <br> ERROR 2041 - Too many QTA tables. <br> ERROR 2041 - Too many SH tables. <br> ERROR 2041 - Too many ST and/or RF tables. <br> ERROR 2041 - Too many SX tables. <br> ERROR 2041 - Too many VC tables. <br> ERROR 2041 - Too many VG tables. <br> ERROR 2041 - Too many VT tables. <br> ERROR 2041 - Too many WT tables.
|type=[[ERROR]]
|message_desc=Found too many or incorrect number of input tables for a boundary type. This Contactis support@tuflow.commost supportlikely to occur if thisa error1d_bc occurslayer (itwhich shouldhas only apply4 toattributes) oldis fixedread fieldinto models)the .tbc. A new error message has been added for the 2016 version of TUFLOW.<br>
This error could also spuriously occur for a model without fixed field inputs if the 2d_bc layer contains the incorrect number of attributes. The 2d_bc layer should contain 8 attributes as follows: Type, Flags, Name, f, d, td, a, b.<br>
|suggestions=????
Though rarely used, the attributes "f" through "b" can be used to apply modifiers on the boundaries (see <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for information), if these are missing, Error 2041 can occur.
|discussion_page=* [[Talk:TUFLOW Message 2041|Discuss Message 2041]]
|suggestions= If the 2d_bc layer has less than 8 attributes, the data should be copied into the correct 2d_bc empty layer.<br>
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_2040|Message 2040]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2042|Message 2042]]
}}