|type=[[CHECK]]
|message_desc=When applying the Engelhund loss approach for manholes (seerefer Sectionto 4the <u>[https://docs.5tuflow.2 of the 2010com/classic-hpc/manual/latest/ TUFLOW manualManual]</u>), if an incoming culvert enters above the obvert of the highest outlet, the culvert is not included in the manhole loss calculations. If there is only 1 incoming pipe with the invert above the obvert of the outlet culvert, the incoming culvert is ignored and with no inlet culvert to the node a manhole is not possible. See also point 48(b) in the <u>[http://www.tuflow.com/Download/TUFLOW/Releases/2012-05/Doc/TUFLOW%20Release%20Notes.2011-09%20and%202012-05.pdf release notes]</u>.
|suggestions=Review the inverts on the culverts. A point object in a "1d_mh" layer can be used to set the loss approach at each manhole.