=Pump Attributes=
A pump needs to first be digitised in a 1d_nwke layer. The direction of the polyline must go from inlet to outlet as a pump is unidirectional (see Section 5.9.2.1 Pumps). The attributes required for a pump in your 1d_nwk layer can be found
In the 1d_nwk layer, the following attributes are required:<br>
#ID = ID of the pump channel. <br>
Line 29:
=Estry Control File Setup=
Within the *.ecf the following commands and files are
<font color="blue"><tt>Read GIS Network</tt></font> <font color="red"><tt>==</tt></font><tt>..\model\mi\1d_nwke_xxxxx.MIF</tt><br>
<font color="blue"><tt>Depth Discharge Database</tt></font> <font color="red"><tt>==</tt></font><tt>..\bc_dbase\xxxxx.csv</tt><br>
Line 35:
=TUFLOW Operating Control File (.TOC)=
For guidance on setting up the operating controls for pumps,
.ecf command required: <br>
Line 42:
=Depth Discharge Database=
The depth discharge database is set up in the same way as a pit inlet database
==Pump Curve==
Line 64:
==Using a Pump Curve in a TUFLOW Operating Control (TOC) File==
With the pump curve defined in the depth-discharge database it can either be specified within the pump 1d_nwk fields in the inlet_type field, for non-operational pumps, or it can be defined with the TOC file, for operational pumps. When defining with a TOC file, the pump curve is defined at the top of the structure control definition block and then the subsequent rules can turn the pump on/off. See the below TOC structure control definition for an example. In this case, the pump curve is used when the pump switches on once upstream water levels reach 2.75m AD.
<font color="blue"><tt>Define Pump Control</tt></font><font color="red"><tt> ==</tt></font> Pump_1
Line 89:
Any further questions please email TUFLOW support: [mailto:support@tuflow.com?Subject=TUFLOW%201D%20pumps%20help support@tuflow.com]