Difference between revisions of "Check Files 2d uvpt"
Jump to navigation
Jump to search
(6 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | This GIS file contains information about the cell sides (U and V points). | + | == Introduction == |
− | + | This GIS file contains information about the cell sides (U and V points). | |
− | + | ||
+ | == Attributes of _uvpt_check == | ||
+ | === General Attributes === | ||
{| align="center" class="wikitable" width="75%" | {| align="center" class="wikitable" width="75%" | ||
! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name | ! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name | ||
! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description | ! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description | ||
|- | |- | ||
− | | n||Row number in the TUFLOW domain | + | | n||Row number in the TUFLOW domain. |
|- | |- | ||
− | | m||Column number in the TUFLOW domain | + | | m||Column number in the TUFLOW domain. |
|- | |- | ||
− | | Type||Zpt type (U or V) | + | | Type||Zpt type (U or V). |
|- | |- | ||
− | | Init_Vel||Initial Velocity | + | | Init_Vel||Initial Velocity. |
|- | |- | ||
− | | Mannings_n (default)<br>Chezy_Coeff<br>Mannings_M ||Roughness coefficient | + | | Mannings_n (default)<br>Chezy_Coeff<br>Mannings_M ||Roughness coefficient. |
|- | |- | ||
− | | FLC||Additional form loss applied | + | | FLC||Additional form loss applied. |
|- | |- | ||
| WrF||Weir factor. | | WrF||Weir factor. | ||
Line 22: | Line 24: | ||
| FC_Depth_to_Lid (only if the model has flow constrictions)||For flow constrictions, the depth to the obvert. | | FC_Depth_to_Lid (only if the model has flow constrictions)||For flow constrictions, the depth to the obvert. | ||
|- | |- | ||
− | | FC_BD_Factor (only if the model has flow constrictions)||For flow constrictions, the bridge deck factor | + | | FC_BD_Factor (only if the model has flow constrictions)||For flow constrictions, the bridge deck factor. |
|- | |- | ||
| FC_Width_Factor (only if the model has flow constrictions)||For flow constrictions, the flow width factor. | | FC_Width_Factor (only if the model has flow constrictions)||For flow constrictions, the flow width factor. | ||
|- | |- | ||
− | | Domain_Index||The index of the model domain. This is the order with <tt>Start 2D Domain == <Domain Name></tt> commands appears in the | + | | Domain_Index||The index of the model domain. This is the order with <tt><font color="blue">Start 2D Domain </font><font color="red">== </font><Domain Name></tt> commands appears in the TCF control file. For a single domain model this will be 1. |
|} | |} | ||
+ | :'''Example _uvpt_check attribute table:''' | ||
+ | :[[File:2d_uvpt_Reg_attribute_table_01.png]] | ||
+ | |||
+ | |||
+ | === Attributes when using quadtree === | ||
+ | {| align="center" class="wikitable" width="75%" | ||
+ | ! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name | ||
+ | ! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description | ||
+ | |- | ||
+ | | qpc_id||The quadtree cell ID. | ||
+ | |- | ||
+ | | Type||Zpt type (U or V). | ||
+ | |- | ||
+ | | Init_Vel||Initial Velocity. | ||
+ | |- | ||
+ | | Mannings_n (default)<br>Chezy_Coeff<br>Mannings_M ||Roughness coefficient. | ||
+ | |} | ||
+ | :'''Example _uvpt_check attribute table (using Quadtree):''' | ||
+ | :[[File:2d_uvpt_Quad_attribute_table_01.png]] | ||
+ | <br> | ||
+ | |||
+ | == Features == | ||
+ | The image below shows the _uvpt_check styled by the Manning's n value. Note if using depth varying varying roughness the Material ID attribute in the <u>[[Check_Files_2d_grd | _grd_check file]]</u> may be preferred.<br> | ||
+ | <br> | ||
+ | [[File:Check Files uvpt n 01.jpg]] | ||
+ | <br><br> | ||
+ | |||
+ | |||
+ | {{Tips Navigation | ||
+ | |uplink=[[TUFLOW_Check_Files | TUFLOW Check Files]] | ||
+ | }} |
Latest revision as of 09:43, 28 October 2024
Introduction
This GIS file contains information about the cell sides (U and V points).
Attributes of _uvpt_check
General Attributes
Attribute Name | Attribute Description |
---|---|
n | Row number in the TUFLOW domain. |
m | Column number in the TUFLOW domain. |
Type | Zpt type (U or V). |
Init_Vel | Initial Velocity. |
Mannings_n (default) Chezy_Coeff Mannings_M |
Roughness coefficient. |
FLC | Additional form loss applied. |
WrF | Weir factor. |
FC_Depth_to_Lid (only if the model has flow constrictions) | For flow constrictions, the depth to the obvert. |
FC_BD_Factor (only if the model has flow constrictions) | For flow constrictions, the bridge deck factor. |
FC_Width_Factor (only if the model has flow constrictions) | For flow constrictions, the flow width factor. |
Domain_Index | The index of the model domain. This is the order with Start 2D Domain == <Domain Name> commands appears in the TCF control file. For a single domain model this will be 1. |
Attributes when using quadtree
Attribute Name | Attribute Description |
---|---|
qpc_id | The quadtree cell ID. |
Type | Zpt type (U or V). |
Init_Vel | Initial Velocity. |
Mannings_n (default) Chezy_Coeff Mannings_M |
Roughness coefficient. |
Features
The image below shows the _uvpt_check styled by the Manning's n value. Note if using depth varying varying roughness the Material ID attribute in the _grd_check file may be preferred.
Up |
---|
TUFLOW Check Files |