TUFLOW Message
CHECK 5013 - Ignoring Constant for variable "<var_name>" as it is not active.
Alternate Message
CHECK 5013 - Ignoring Time-Series for variable "<var_name>" as it is not active.
Message Type
CHECK
Description
Ignoring Constant/Time-Series for variable "<var_name>" as it is not active. In the TUFLOW CATCH control file (.tcc), the variable "<var_name>" has not been defined in the catchment hydraulic model block (" Pollutant == " command), but is then referenced in the pollutant export model block via the " Constant <var_name> == " or " Time-Series <var_name> == " command. As the variable "<var_name>" is not being simulated, it is ignored.
Suggestions
Comment out the " Constant <var_name> == " or " Time-Series <var_name> == " command.