We are currently working on an updated version of the dat_to_dat utility which includes support for the XMDF file type.  This page will be updated when this is complete.
+
This utility performs a variety of operations on the TUFLOW 2D outputs.  Valid formats are .xmdf (as of utility version 2012-10-AC) and .dat files.  This page is split into two section, utility operations (e.g. maximum, difference etc.) and general options.  The general options can be used regardless of operation being performed.  The table of contents can be used to jump to a desired operation.
=Examples=
+
 
For examples on the current dat_to_dat utility please see section 11.3 of the 2010 TUFLOW manual.
+
=Operations=
 +
The section below contains a list of the operations that the utility can perform.  One of these operations must be specified or the utility will generate an error.
 +
 
 +
==Max==
 +
'''Input Switch: -max'''<br>
 +
<u>Description</u><br>
 +
This can be used to extract the maximum from a number of input datasets.  Any number of input files can be specified.  If a maximum folder exists in an .xmdf file for the type specified, this dataset will be used, for dat files use -t99999 to use the maximum data in the .dat file.<br>
 +
<u>Examples</u><br>
 +
<li><tt>dat_to_dat.exe -max results_1_h.dat results_2_h.dat results_3_h.dat</tt></li>
 +
Extracts the maximum water level from the three .dat files.
 +
<li><tt>dat_to_dat.exe -max -typeH results_1.xmdf results_2.xmdf results_3.xmdf</tt></li>
 +
As above but for results stored in xmdf file format.
 +
 
 +
==Difference==
 +
'''Input Switch: -dif'''<br>
 +
<u>Description</u><br>
 +
This can be used to compare two datasets.  If a third files is specified, the third file is used as the output file.  The output filename can also be specified with the -out option.  The output is the first results minus the second result file.<br>
 +
A special wet/dry algorithm is used.  If water level results are not specified (_h.dat or -typeH), the algorithm opens these files, as well as opens the .2dm file associated with the results files, and uses the water levels and ZH Zpt values (for 2D cells) and elevations at the WLL triangle corners to determine whether a node (corner of an mesh element) is wet or dry.  This allows two special values to be output in the event that a node is dry in one results file and wet in the other or vice versa.  A value of  99 is used to indicate that a node is dry in the first results file, but is flooded in the second results file, while +99 indicates that the node was wet in the first results file but is dry in the second results file.  Specifying '''-nowetdry''' does not carry out a wet/dry check using  the water level results.
 +
<br>
 +
The  -t option can be used to carry out the difference at a particular time (rather than all times).  The most common time is to take the difference at the flood peak, ie. specify t99999.<br>
 +
<u>Examples</u><br>
 +
<li><tt>dat_to_dat.exe -dif results_developed_h.dat results_existing_h.dat</tt></li>
 +
Extracts the difference in water level, the output is results_developed_h - results_existing_h for all timesteps.
 +
<li><tt>dat_to_dat.exe -dif -typeH -nowetdry results_developed.xmdf results_existing.xmdf</tt></li>
 +
Extracts the difference in water level for the maximum water level and suppresses the wet/dry check described above.
 +
 
 +
==Duration==
 +
'''Input Switch: -dur<cut of value>'''<br>
 +
<u>Description</u><br>
 +
Determines the duration in hours that the the results exceed the cut of value.<br>
 +
'''Note: ''' A preferable approach is to use the .tcf file command: <tt>Time Output Cutoff Depths == <cut of value or values></tt>.  With this command specified TUFLOW tracks this on a timestep by timestep basis rather than post processing this at the map output interval.<br>
 +
<u>Examples</u><br>
 +
<li><tt>dat_to_dat.exe -dur0.1 -typeD results.xmdf</tt></li>
 +
Extracts the duration in flooding above 0.1m deep.
 +
 
 +
==Keep==
 +
'''Input Switch: -k<output time>'''<br>
 +
<u>Description</u><br>
 +
Can be used to extract a single timestep from a results file.  This is useful to extract the maximums to a separate file making it easier to transfer electronically.  To keep a range of output times see the -range option below.<br>
 +
<u>Examples</u><br>
 +
<li><tt>dat_to_dat.exe -k99999 results_h.dat</tt></li>
 +
Creates a new results file containing just the maximum from the water level results.
 +
<li><tt>dat_to_dat.exe -k2.5 -typeV results.xmdf</tt></li>
 +
Creates a new results file containing just velocity results for the 2.5 hour output.
 +
 
 +
==Range==
 +
'''Input Switch: -rangeA<start time> -rangeB<end time>'''<br>
 +
<u>Description</u><br>
 +
Extracts all timestep between start time and end time (inclusive) into a separate results file.<br>
 +
<u>Examples</u><br>
 +
<li><tt>dat_to_dat.exe -rangeA1 -rangeB2.5 results_q.dat</tt></li>
 +
Creates a new results file containing the outputs between 1.0 and 2.5 hours.  Both 1 and 2.5 hour outputs are included.
 +
<li><tt>dat_to_dat.exe -rangeA1 -rangeB2.5 results.xmdf</tt></li>
 +
As above but for xmdf input files.
 +
 
 +
==Remove==
 +
'''Input Switch: -r<output time>'''<br>
 +
<u>Description</u><br>
 +
Creates a new output file and removes the output time from this.<br>
 +
<u>Examples</u><br>
 +
<li><tt>dat_to_dat.exe -r3 results_d.dat</tt></li>
 +
Creates a new output file which does not include the output at 3.
 +
 
 +
==Trim Values==
 +
'''Input Switch: -trim<value>'''<br>
 +
<u>Description</u><br>
 +
Creates a new output file which has any values above <value> set to <value>.  If the input is a vector data, the vector magnitude is used to trim the value (direction is unchanged).<br>
 +
<u>Examples</u><br>
 +
<li><tt>dat_to_dat.exe -trim5 -typeV results.xmdf</tt></li>
 +
Creates a new output of velocity with any outputs greater than 5.0 set to 5.0.
 +
 
 +
==Times==
 +
'''Input Switch: -times'''<br>
 +
<u>Description</u><br>
 +
Creates a text file which contains the output times in the .dat or xmdf file.  If no output filename is specified with the -out option the output file will be called "times.txt".  For xmdf files see also the -xnfo option below.<br>
 +
<u>Examples</u><br>
 +
<li><tt>dat_to_dat.exe -times results_h.dat</tt></li>
 +
Creates an an output file "times.txt" which contains all timesteps that are contained in the results file.
 +
 
 +
==XMDF Information==
 +
'''Input Switch: -xnfo'''<br>
 +
<u>Description</u><br>
 +
Creates a text file which contains a list of the datasets contained within the .xmdf file.  The number of output times and the output times are also exported to the text file.<br>
 +
<u>Examples</u><br>
 +
<li><tt>dat_to_dat.exe -xnfo -out xmdf_info.txt results.xmdf</tt></li>
 +
Creates an an output file with the specified filename "xmdf_info.txt", which contains information about the contents of the xmdf file.
 +
 
 +
==Vector Angle==
 +
'''Input Switch: -va'''<br>
 +
<u>Description</u><br>
 +
Outputs the vector direction in degrees relative to north (North = 0°, East = 90°, South = 180°/-180°, West = -90°).
 +
<u>Examples</u><br>
 +
<li><tt>dat_to_dat.exe -va results_v.dat</tt></li>
 +
Outputs the velocity direction for all timesteps in the results_V.dat file.
 +
==Concatenate==
 +
'''Input Switch: -con'''<br>
 +
<u>Description</u><br>
 +
Concatenates (joins)  two or more results files into one.  Each results file must be from the same 1D/2D mesh.
 +
<u>Examples</u><br>
 +
<li><tt>dat_to_dat.exe -con results1_h.dat results2_h.dat results3_h.dat</tt></li>
 +
Joins the three files into a single .dat file.
 +
<li><tt>dat_to_dat.exe -con -typeH results1.xmdf results2.xmdf results3.xmdf</tt></li>
 +
Joins the water level results contained in the .xmdf files into a single
 +
 
 +
==Convert==
 +
'''Input Switch: -conv'''<br>
 +
<u>Description</u><br>
 +
Converts between .dat and .xmdf format results.  Not to be confused with -con (concatenate option described above)!
 +
<u>Examples</u><br>
 +
<li><tt>dat_to_dat.exe -conv -typeH -t99999 results1.xmdf</tt></li>
 +
Converts the maximum water level results in the xmdf file into .dat file format.
 +
<li><tt>dat_to_dat.exe -conv results1.xmdf</tt></li>
 +
Converts all datasets and times in the .xmdf file into .dat file format.  This will output a number of .dat files.
 +
<li><tt>dat_to_dat.exe -conv results1_h.dat</tt></li>
 +
Converts all times in the .dat file into xmdf file format.
 +
 
 +
==Ensight (beta)==
 +
'''Input Switch: -ensight'''<br>
 +
<u>Description</u><br>
 +
Converts an .xmdf file (.dat not yet supported) into Ensight Gold format.<br>
 +
If the input dataset is corner based (standard output) the Ensight results are output as scalar / vector '''per node''' (cell and triangle corners).<br>
 +
If the result is high resolution (Map Output Format == xmdf high res) then the Ensight results are '''per element'''.  For 2D cells this is based on the cell centre output, for triangles (1D water level lines) this is based on an interpolation of the triangle vertices.
 +
The conversion produces the following output files:<br>
 +
* Ensight case file;
 +
* Ensight geometry file;
 +
* Ensight results as either per node or per element depending on the input file.
 +
'''This conversion is in beta stage and any feedback can be sent to support@tuflow.com.<br>
 +
<u>Examples</u><br>
 +
<li><tt>dat_to_dat.exe -ensight results1.xmdf</tt></li>
 +
Converts all datasets in the xmdf file into Ensight format.
 +
 
 +
=General Options=
 +
==Batch Mode==
 +
'''Input Switch: -b'''<br>
 +
Batch mode suppresses prompt to press Enter at end of processing.  Used in .bat files where two or more files are to be processed in succession.
 +
==Output Filename==
 +
'''Input Switch: -out "output_filename"'''<br>
 +
Sets the output filename.
 +
 
 
{{Tips Navigation
 
{{Tips Navigation
 
|uplink=[[TUFLOW_Utilities | Back to TUFLOW Utilities]]
 
|uplink=[[TUFLOW_Utilities | Back to TUFLOW Utilities]]
 
}}
 
}}
 +
 +
</ol>

Latest revision as of 05:47, 28 October 2012

    Introduction

    This utility performs a variety of operations on the TUFLOW 2D outputs. Valid formats are .xmdf (as of utility version 2012-10-AC) and .dat files. This page is split into two section, utility operations (e.g. maximum, difference etc.) and general options. The general options can be used regardless of operation being performed. The table of contents can be used to jump to a desired operation.

    Operations

    The section below contains a list of the operations that the utility can perform. One of these operations must be specified or the utility will generate an error.

    Max

    Input Switch: -max
    Description
    This can be used to extract the maximum from a number of input datasets. Any number of input files can be specified. If a maximum folder exists in an .xmdf file for the type specified, this dataset will be used, for dat files use -t99999 to use the maximum data in the .dat file.
    Examples

  1. dat_to_dat.exe -max results_1_h.dat results_2_h.dat results_3_h.dat
  2. Extracts the maximum water level from the three .dat files.
  3. dat_to_dat.exe -max -typeH results_1.xmdf results_2.xmdf results_3.xmdf
  4. As above but for results stored in xmdf file format.

    Difference

    Input Switch: -dif
    Description
    This can be used to compare two datasets. If a third files is specified, the third file is used as the output file. The output filename can also be specified with the -out option. The output is the first results minus the second result file.
    A special wet/dry algorithm is used. If water level results are not specified (_h.dat or -typeH), the algorithm opens these files, as well as opens the .2dm file associated with the results files, and uses the water levels and ZH Zpt values (for 2D cells) and elevations at the WLL triangle corners to determine whether a node (corner of an mesh element) is wet or dry. This allows two special values to be output in the event that a node is dry in one results file and wet in the other or vice versa. A value of 99 is used to indicate that a node is dry in the first results file, but is flooded in the second results file, while +99 indicates that the node was wet in the first results file but is dry in the second results file. Specifying -nowetdry does not carry out a wet/dry check using the water level results.
    The -t option can be used to carry out the difference at a particular time (rather than all times). The most common time is to take the difference at the flood peak, ie. specify t99999.
    Examples

  5. dat_to_dat.exe -dif results_developed_h.dat results_existing_h.dat
  6. Extracts the difference in water level, the output is results_developed_h - results_existing_h for all timesteps.
  7. dat_to_dat.exe -dif -typeH -nowetdry results_developed.xmdf results_existing.xmdf
  8. Extracts the difference in water level for the maximum water level and suppresses the wet/dry check described above.

    Duration

    Input Switch: -dur<cut of value>
    Description
    Determines the duration in hours that the the results exceed the cut of value.
    Note: A preferable approach is to use the .tcf file command: Time Output Cutoff Depths == <cut of value or values>. With this command specified TUFLOW tracks this on a timestep by timestep basis rather than post processing this at the map output interval.
    Examples

  9. dat_to_dat.exe -dur0.1 -typeD results.xmdf
  10. Extracts the duration in flooding above 0.1m deep.

    Keep

    Input Switch: -k<output time>
    Description
    Can be used to extract a single timestep from a results file. This is useful to extract the maximums to a separate file making it easier to transfer electronically. To keep a range of output times see the -range option below.
    Examples

  11. dat_to_dat.exe -k99999 results_h.dat
  12. Creates a new results file containing just the maximum from the water level results.
  13. dat_to_dat.exe -k2.5 -typeV results.xmdf
  14. Creates a new results file containing just velocity results for the 2.5 hour output.

    Range

    Input Switch: -rangeA<start time> -rangeB<end time>
    Description
    Extracts all timestep between start time and end time (inclusive) into a separate results file.
    Examples

  15. dat_to_dat.exe -rangeA1 -rangeB2.5 results_q.dat
  16. Creates a new results file containing the outputs between 1.0 and 2.5 hours. Both 1 and 2.5 hour outputs are included.
  17. dat_to_dat.exe -rangeA1 -rangeB2.5 results.xmdf
  18. As above but for xmdf input files.

    Remove

    Input Switch: -r<output time>
    Description
    Creates a new output file and removes the output time from this.
    Examples

  19. dat_to_dat.exe -r3 results_d.dat
  20. Creates a new output file which does not include the output at 3.

    Trim Values

    Input Switch: -trim<value>
    Description
    Creates a new output file which has any values above <value> set to <value>. If the input is a vector data, the vector magnitude is used to trim the value (direction is unchanged).
    Examples

  21. dat_to_dat.exe -trim5 -typeV results.xmdf
  22. Creates a new output of velocity with any outputs greater than 5.0 set to 5.0.

    Times

    Input Switch: -times
    Description
    Creates a text file which contains the output times in the .dat or xmdf file. If no output filename is specified with the -out option the output file will be called "times.txt". For xmdf files see also the -xnfo option below.
    Examples

  23. dat_to_dat.exe -times results_h.dat
  24. Creates an an output file "times.txt" which contains all timesteps that are contained in the results file.

    XMDF Information

    Input Switch: -xnfo
    Description
    Creates a text file which contains a list of the datasets contained within the .xmdf file. The number of output times and the output times are also exported to the text file.
    Examples

  25. dat_to_dat.exe -xnfo -out xmdf_info.txt results.xmdf
  26. Creates an an output file with the specified filename "xmdf_info.txt", which contains information about the contents of the xmdf file.

    Vector Angle

    Input Switch: -va
    Description
    Outputs the vector direction in degrees relative to north (North = 0°, East = 90°, South = 180°/-180°, West = -90°). Examples

  27. dat_to_dat.exe -va results_v.dat
  28. Outputs the velocity direction for all timesteps in the results_V.dat file.

    Concatenate

    Input Switch: -con
    Description
    Concatenates (joins) two or more results files into one. Each results file must be from the same 1D/2D mesh. Examples

  29. dat_to_dat.exe -con results1_h.dat results2_h.dat results3_h.dat
  30. Joins the three files into a single .dat file.
  31. dat_to_dat.exe -con -typeH results1.xmdf results2.xmdf results3.xmdf
  32. Joins the water level results contained in the .xmdf files into a single

    Convert

    Input Switch: -conv
    Description
    Converts between .dat and .xmdf format results. Not to be confused with -con (concatenate option described above)! Examples

  33. dat_to_dat.exe -conv -typeH -t99999 results1.xmdf
  34. Converts the maximum water level results in the xmdf file into .dat file format.
  35. dat_to_dat.exe -conv results1.xmdf
  36. Converts all datasets and times in the .xmdf file into .dat file format. This will output a number of .dat files.
  37. dat_to_dat.exe -conv results1_h.dat
  38. Converts all times in the .dat file into xmdf file format.

    Ensight (beta)

    Input Switch: -ensight
    Description
    Converts an .xmdf file (.dat not yet supported) into Ensight Gold format.
    If the input dataset is corner based (standard output) the Ensight results are output as scalar / vector per node (cell and triangle corners).
    If the result is high resolution (Map Output Format == xmdf high res) then the Ensight results are per element. For 2D cells this is based on the cell centre output, for triangles (1D water level lines) this is based on an interpolation of the triangle vertices. The conversion produces the following output files:

    • Ensight case file;
    • Ensight geometry file;
    • Ensight results as either per node or per element depending on the input file.

    This conversion is in beta stage and any feedback can be sent to support@tuflow.com.
    Examples

  39. dat_to_dat.exe -ensight results1.xmdf
  40. Converts all datasets in the xmdf file into Ensight format.

    General Options

    Batch Mode

    Input Switch: -b
    Batch mode suppresses prompt to press Enter at end of processing. Used in .bat files where two or more files are to be processed in succession.

    Output Filename

    Input Switch: -out "output_filename"
    Sets the output filename.

    Up
    Go-up.png Back to TUFLOW Utilities