Difference between revisions of "Check Files 2d fcsh uvpt"

From Tuflow
Jump to navigation Jump to search
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
Contains information on the cell sides (U and V points) that have a flow constriction shape object applied.  This contains information on the processed elevations, blockages and form loss values applied at the cell side.
+
Contains information on the cell sides (U and V points) that have a flow constriction shape object applied.  This contains information on the processed elevations, blockages and form loss values applied at the cell side.<br>
 +
'''Note:''' This file is only created for the older 2d_fcsh layers (<tt><font color=blue>Read GIS FC Shape</font><font color=red> == </font></tt>). The newer <u>[[Check_Files_2d_lfcsh_uvpt | Layered Flow Constriction Shapes (2d_lfcsh)]]</u> has a separate check file.
 
<br>
 
<br>
  
'''Attributes of fcsh_uvpt'''<br>
+
'''Attributes of _fcsh_uvpt_check'''<br>
 
{| align="center" class="wikitable" width="75%"
 
{| align="center" class="wikitable" width="75%"
 
! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name
 
! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name
 
! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description
 
! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description
 
|-
 
|-
| FC_Type||The flow constriction type as described in the <u>[https://downloads.tuflow.com/TUFLOW/Releases/Latest/TUFLOW%20Manual.pdf TUFLOW Manual]</u>.
+
| FC_Type||The flow constriction type:
 +
* Blank for general
 +
* "BC" for box culverts
 +
* "BD" for bridge deck
 +
* "FD" for floating bridge deck
 +
For further information, refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u>.
 
|-
 
|-
 
| Z_Bed||The ground level of the z point.
 
| Z_Bed||The ground level of the z point.

Latest revision as of 14:48, 5 August 2025

Contains information on the cell sides (U and V points) that have a flow constriction shape object applied. This contains information on the processed elevations, blockages and form loss values applied at the cell side.
Note: This file is only created for the older 2d_fcsh layers (Read GIS FC Shape == ). The newer Layered Flow Constriction Shapes (2d_lfcsh) has a separate check file.

Attributes of _fcsh_uvpt_check

Attribute Name Attribute Description
FC_Type The flow constriction type:
  • Blank for general
  • "BC" for box culverts
  • "BD" for bridge deck
  • "FD" for floating bridge deck

For further information, refer to the TUFLOW Manual.

Z_Bed The ground level of the z point.
Obvert_or_BC_H_or_FD_Depth This attribute is dependent on the FC type:
  • For a blank flow or "BD" constriction type this is the structure obvert. Above this elevation there is no additional flow area.
  • For a "BC" constriction type this is the height of the box culvert.
  • For a "FD" constriction type this is the depth of the object.
pBlockage The percentage (%) blockage of below the deck level, above this the blockage is 100%.
FLC_below_Obvert The Form Loss Coefficient below the structure obvert.
FLC_above_Obvert The Form Loss Coefficient above the structure obvert.
BC_n_or_BD_n For the "BC" or "BD" type constrictions this is the n attribute.
BC_Width For a "BC" type this is the box culvert width.
Source This is the source GIS layer which contains the flow constriction shape.


Up
Go-up.png TUFLOW Check Files