Check Files 2d fcsh uvpt: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
Created page with "To be created"
 
No edit summary
 
(5 intermediate revisions by 2 users not shown)
Line 1: Line 1:
Contains information on the cell sides (U and V points) that have a flow constriction shape object applied. This contains information on the processed elevations, blockages and form loss values applied at the cell side.
To be created

'''Note: This file is only created for 2d_fcsh layers, which are considered legacy and supported by TUFLOW Classic only.''' It is recommended to use the layered flow constriction shape (2d_lfcsh) instead. The 2d_lfcsh has a separate check file: [[Check_Files_2d_lfcsh_uvpt | 2d_lfcsh_uvpt]].


'''Attributes of _fcsh_uvpt_check'''<br>
{| align="center" class="wikitable" width="75%"
! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name
! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description
|-
| FC_Type||The flow constriction type:
* Blank for general
* "BC" for box culverts
* "BD" for bridge deck
* "FD" for floating bridge deck
For further information, refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u>.
|-
| Z_Bed||The ground level of the z point.
|-
| Obvert_or_BC_H_or_FD_Depth|| This attribute is dependent on the FC type:<br>
* For a blank flow or "BD" constriction type this is the structure obvert. Above this elevation there is no additional flow area.
* For a "BC" constriction type this is the height of the box culvert.
* For a "FD" constriction type this is the depth of the object.
|-
| pBlockage||The percentage (%) blockage of below the deck level, above this the blockage is 100%.
|-
| FLC_below_Obvert||The '''F'''orm '''L'''oss '''C'''oefficient below the structure obvert.
|-
| FLC_above_Obvert||The '''F'''orm '''L'''oss '''C'''oefficient above the structure obvert.
|-
| BC_n_or_BD_n||For the "BC" or "BD" type constrictions this is the n attribute.
|-
| BC_Width||For a "BC" type this is the box culvert width.
|-
| Source||This is the source GIS layer which contains the flow constriction shape.
|}


{{Tips Navigation
|uplink=[[TUFLOW_Check_Files | TUFLOW Check Files]]
}}

Latest revision as of 16:11, 16 February 2026

Contains information on the cell sides (U and V points) that have a flow constriction shape object applied. This contains information on the processed elevations, blockages and form loss values applied at the cell side.

Note: This file is only created for 2d_fcsh layers, which are considered legacy and supported by TUFLOW Classic only. It is recommended to use the layered flow constriction shape (2d_lfcsh) instead. The 2d_lfcsh has a separate check file: 2d_lfcsh_uvpt.


Attributes of _fcsh_uvpt_check

Attribute Name Attribute Description
FC_Type The flow constriction type:
  • Blank for general
  • "BC" for box culverts
  • "BD" for bridge deck
  • "FD" for floating bridge deck

For further information, refer to the TUFLOW Manual.

Z_Bed The ground level of the z point.
Obvert_or_BC_H_or_FD_Depth This attribute is dependent on the FC type:
  • For a blank flow or "BD" constriction type this is the structure obvert. Above this elevation there is no additional flow area.
  • For a "BC" constriction type this is the height of the box culvert.
  • For a "FD" constriction type this is the depth of the object.
pBlockage The percentage (%) blockage of below the deck level, above this the blockage is 100%.
FLC_below_Obvert The Form Loss Coefficient below the structure obvert.
FLC_above_Obvert The Form Loss Coefficient above the structure obvert.
BC_n_or_BD_n For the "BC" or "BD" type constrictions this is the n attribute.
BC_Width For a "BC" type this is the box culvert width.
Source This is the source GIS layer which contains the flow constriction shape.


Up
TUFLOW Check Files