Check Files 2d uvpt: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
Created page with "To be created" |
No edit summary |
||
Line 1: | Line 1: | ||
This GIS file contains information about the cell sides (U and V points). <br> |
|||
To be created |
|||
<br> |
|||
'''Attributes of uvpt_check'''<br> |
|||
{| align="center" class="wikitable" width="75%" |
|||
! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name |
|||
! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description |
|||
|- |
|||
| n||Row number in the TUFLOW domain |
|||
|- |
|||
| m||Column number in the TUFLOW domain |
|||
|- |
|||
| Type||Zpt type (U or V) |
|||
|- |
|||
| Init_Vel||Initial Velocity |
|||
|- |
|||
| Mannings_n (default)<br>Chezy_Coeff<br>Mannings_M ||Roughness coefficient |
|||
|- |
|||
| FLC||Additional form loss applied |
|||
|- |
|||
| WrF||Weir factor. |
|||
|- |
|||
| FC_Depth_to_Lid (only if the model has flow constrictions)||For flow constrictions, the depth to the obvert. |
|||
|- |
|||
| FC_BD_Factor (only if the model has flow constrictions)||For flow constrictions, the bridge deck factor |
|||
|- |
|||
| FC_Width_Factor (only if the model has flow constrictions)||For flow constrictions, the flow width factor. |
|||
|- |
|||
| Domain_Index||The index of the model domain. This is the order with <tt>Start 2D Domain == <Domain Name></tt> commands appears in the .tcf control file. For a single domain model this will be 1. |
|||
|} |
Revision as of 16:02, 28 January 2016
This GIS file contains information about the cell sides (U and V points).
Attributes of uvpt_check
Attribute Name | Attribute Description |
---|---|
n | Row number in the TUFLOW domain |
m | Column number in the TUFLOW domain |
Type | Zpt type (U or V) |
Init_Vel | Initial Velocity |
Mannings_n (default) Chezy_Coeff Mannings_M |
Roughness coefficient |
FLC | Additional form loss applied |
WrF | Weir factor. |
FC_Depth_to_Lid (only if the model has flow constrictions) | For flow constrictions, the depth to the obvert. |
FC_BD_Factor (only if the model has flow constrictions) | For flow constrictions, the bridge deck factor |
FC_Width_Factor (only if the model has flow constrictions) | For flow constrictions, the flow width factor. |
Domain_Index | The index of the model domain. This is the order with Start 2D Domain == <Domain Name> commands appears in the .tcf control file. For a single domain model this will be 1. |