Difference between revisions of "TUFLOW Message 2030"
Jump to navigation
Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ,...') |
|||
(7 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message= | + | |tuflow_message=ERROR 2030 - Trying to apply a HT or HS boundary to a 2D cell already assigned a link or a HQ, Q or S boundary. |
+ | |alt_msg=NA | ||
+ | |type=[[ERROR]] | ||
|message_desc=Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary). | |message_desc=Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary). | ||
− | |suggestions= | + | |suggestions=Separate incompatible boundary types, for example a single 2D cell cannot be both a water level boundary and a flow boundary. The <u>[[Check_Files_2d_bcc_check | bcc_check]]</u> layer is useful identifying cells acting as boundaries. |
− | + | ||
− | + | ||
− | + | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |
− | |||
− | | | ||
}} | }} |
Latest revision as of 11:00, 23 December 2022
TUFLOW Message
ERROR 2030 - Trying to apply a HT or HS boundary to a 2D cell already assigned a link or a HQ, Q or S boundary.
Alternate Message
NA
Message Type
ERROR
Description
Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary).
Suggestions
Separate incompatible boundary types, for example a single 2D cell cannot be both a water level boundary and a flow boundary. The bcc_check layer is useful identifying cells acting as boundaries.
Up |
---|
2xxx Messages |