Difference between revisions of "TUFLOW Message 1298"
Jump to navigation
Jump to search
(2 intermediate revisions by 2 users not shown) | |||
Line 5: | Line 5: | ||
|message_desc=1D timestep must be must be less than or equal to the timestep of the 2D model. If multiple 2D domains are used the 1D timestep must be less than or equal to the smallest timestep in any of the 2D domains. If using a 1D timestep smaller than 2D timestep, the 2D timestep needs to be divisible by the 1D timestep. For example a with a 2D timestep of 4 seconds a 1D timestep of 1 or 2 seconds is ok, but 2.5 not valid. | |message_desc=1D timestep must be must be less than or equal to the timestep of the 2D model. If multiple 2D domains are used the 1D timestep must be less than or equal to the smallest timestep in any of the 2D domains. If using a 1D timestep smaller than 2D timestep, the 2D timestep needs to be divisible by the 1D timestep. For example a with a 2D timestep of 4 seconds a 1D timestep of 1 or 2 seconds is ok, but 2.5 not valid. | ||
|suggestions=Specify a 1D timestep less than or equal to the 2D timestep or the smallest 2D timestep for a multiple 2D domain model. | |suggestions=Specify a 1D timestep less than or equal to the 2D timestep or the smallest 2D timestep for a multiple 2D domain model. | ||
− | + | ||
− | |||
− | |||
− | |||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 10:25, 23 December 2022
TUFLOW Message
WARNING 1298 - 1D timestep must be less than or equal to smallest timestep from the 2D domains
Alternate Message
NA
Message Type
WARNING
Description
1D timestep must be must be less than or equal to the timestep of the 2D model. If multiple 2D domains are used the 1D timestep must be less than or equal to the smallest timestep in any of the 2D domains. If using a 1D timestep smaller than 2D timestep, the 2D timestep needs to be divisible by the 1D timestep. For example a with a 2D timestep of 4 seconds a 1D timestep of 1 or 2 seconds is ok, but 2.5 not valid.
Suggestions
Specify a 1D timestep less than or equal to the 2D timestep or the smallest 2D timestep for a multiple 2D domain model.
Up |
---|
1xxx Messages |