| {{TUFLOW_Message | {{TUFLOW_Message | ||
| |tuflow_message= | |tuflow_message=ERROR 2194 - Column 1 values not ascending in ",a," table | ||
| | | |alt_msg=ERROR 2194 - Column 1 values not ascending in ",a," table. | ||
| |type=[[ERROR]] | |||
| |suggestions=???? | |||
| |message_desc=Column 1 values not ascending in a boundary condition table.  Table data is output to the .tlf file and console. For a Head-Time the first column is the time data, time values should be unique and in ascending order. The same applies to all boundary condition types.  For a HQ (stage-discharge, or rating curve) the height values should be increasing.  | |||
| |discussion_page=* [[Talk:TUFLOW Message 2194|Discuss Message 2194]] | |||
| |suggestions=Check data, remove duplicate values and sort by first column. Note for TUFLOW build 2012-05-AC, consecutive flow values in automatic 2D HQ boundary tables are now automatically removed. | |||
| |link3='' | |||
| |link4='' | |||
| |prelink=[[TUFLOW_Message_2193|Message 2193]] | |||
| |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |||
| |nextlink=[[TUFLOW_Message_2195|Message 2195]] | |||
| }} | }} | ||
Latest revision as of 13:58, 7 February 2023
TUFLOW Message 
ERROR 2194 - Column 1 values not ascending in ",a," table
Alternate Message 
ERROR 2194 - Column 1 values not ascending in ",a," table.
Message Type 
ERROR
Description 
Column 1 values not ascending in a boundary condition table.  Table data is output to the .tlf file and console. For a Head-Time the first column is the time data, time values should be unique and in ascending order. The same applies to all boundary condition types.  For a HQ (stage-discharge, or rating curve) the height values should be increasing.
Suggestions 
Check data, remove duplicate values and sort by first column. Note for TUFLOW build 2012-05-AC, consecutive flow values in automatic 2D HQ boundary tables are now automatically removed.