TUFLOW Message 2194: Difference between revisions

Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=Column 1 values not ascending in a boundary condition table. Table data is output to the .tlf file and console. |suggestions=...'
 
No edit summary
 
(4 intermediate revisions by 3 users not shown)
Line 1:
{{TUFLOW_Message
|tuflow_message=????ERROR 2194 - Column 1 values not ascending in ",a," table
|message_descalt_msg=ERROR 2194 - Column 1 values not ascending in ",a boundary condition," table. Table data is output to the .tlf file and console.
|type=[[ERROR]]
|suggestions=????
|message_desc=Column 1 values not ascending in a boundary condition table. Table data is output to the .tlf file and console. For a Head-Time the first column is the time data, time values should be unique and in ascending order. The same applies to all boundary condition types. For a HQ (stage-discharge, or rating curve) the height values should be increasing.
|discussion_page=* [[Talk:TUFLOW Message 2194|Discuss Message 2194]]
|suggestions=Check data, remove duplicate values and sort by first column. Note for TUFLOW build 2012-05-AC, consecutive flow values in automatic 2D HQ boundary tables are now automatically removed.
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_2193|Message 2193]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2195|Message 2195]]
 
}}