Latest revision as of 09:37, 23 September 2024

TUFLOW Message
ERROR 2016 - Unrecognisable 2D connection specified for pit or manhole.

Alternate Message
NA

Message Type
ERROR

Description
Unrecognisable 2D connection specified for pit or manhole.

Suggestions
The Conn_2D attribute in the 1d_nwk can be used to create a 2D connection. Valid options are:

  • SX
  • SXZ
  • SXL
  • SXG
  • SXS

For more information on these, refer to the TUFLOW Manual.

If you are using th GPU virtual pipes feature, this error may occur if you have spcified the 'Width' or 'Conn_No' as Zero


Up
Go-up.png 2xxx Messages