Check Files 1d nwk N: Difference between revisions

Content deleted Content added
No edit summary
No edit summary
 
(2 intermediate revisions by 2 users not shown)
Line 19:
| ANA||Any additional nodal area that has been added at the node (value in square metres or square feet).
|-
| Conn_1D_2D||The 1D/2D connection method (if used) otherwise set to "----". See the <u>[https://downloadsdocs.tuflow.com/TUFLOWclassic-hpc/Releasesmanual/Latestlatest/TUFLOW%20Manual.pdf TUFLOW Manual]</u> for a list of 1D/2D connection methods.
|-
| Conn_Width||The connection width of the 1D/2D connection, this is used for determining how many 2D cells to connect to.
Line 29:
| R3||Not used.
|-
| i_1d_layer||The index to the input layer that has created the manhole. For example an i_1d_nwki_1d_layer value of 2 would be the 2nd input layer (1d_nwk_M05_pits_001_P) below.<br>
<font color="blue"><tt>Read GIS Network </tt></font> <font color="red"><tt>==</tt></font><tt> 1d_nwk_M05_pipes_001_L</tt><br>
<font color="blue"><tt>Read GIS Network </tt></font> <font color="red"><tt>==</tt></font><tt> 1d_nwk_M05_pits_001_P</tt><br>
Line 35:
| No_Channels||Number of channels the node is connected to.
|-
| Pit_Connected||'''"Y"''' (Yes) if the node has a 1D/2Dpit connection, '''"N"''' (No) if not.
|}