Check Files 2d uvpt: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
 
(3 intermediate revisions by the same user not shown)
Line 31: Line 31:
|}
|}
:'''Example _uvpt_check attribute table:'''
:'''Example _uvpt_check attribute table:'''
:[[File:]]
:[[File:2d_uvpt_Reg_attribute_table_01.png]]




=== SGS Specific Arributes ===
=== Attributes when using quadtree ===
{| align="center" class="wikitable" width="75%"
{| align="center" class="wikitable" width="75%"
! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name
! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name
! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description
! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description
|-
|-
| qpc_id||The quadtree cell ID.
| n||Row number in the TUFLOW domain.
|-
| m||Column number in the TUFLOW domain.
|-
|-
| Type||Zpt type (U or V).
| Type||Zpt type (U or V).
Line 48: Line 46:
|-
|-
| Mannings_n (default)<br>Chezy_Coeff<br>Mannings_M ||Roughness coefficient.
| Mannings_n (default)<br>Chezy_Coeff<br>Mannings_M ||Roughness coefficient.
|-
| FLC||Additional form loss applied.
|-
| WrF||Weir factor.
|-
| FC_Depth_to_Lid (only if the model has flow constrictions)||For flow constrictions, the depth to the obvert.
|-
| FC_BD_Factor (only if the model has flow constrictions)||For flow constrictions, the bridge deck factor.
|-
| FC_Width_Factor (only if the model has flow constrictions)||For flow constrictions, the flow width factor.
|-
| Domain_Index||The index of the model domain. This is the order with <tt><font color="blue">Start 2D Domain </font><font color="red">== </font><Domain Name></tt> commands appears in the TCF control file. For a single domain model this will be 1.
|}
:'''Example _uvpt_check attribute table (using SGS):'''
:[[File:]]

=== Quadtree Specific Attributes ===
{| align="center" class="wikitable" width="75%"
! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name
! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description
|-
| n||Row number in the TUFLOW domain.
|-
| m||Column number in the TUFLOW domain.
|-
| Type||Zpt type (U or V).
|-
| Init_Vel||Initial Velocity.
|-
| Mannings_n (default)<br>Chezy_Coeff<br>Mannings_M ||Roughness coefficient.
|-
| FLC||Additional form loss applied.
|-
| WrF||Weir factor.
|-
| FC_Depth_to_Lid (only if the model has flow constrictions)||For flow constrictions, the depth to the obvert.
|-
| FC_BD_Factor (only if the model has flow constrictions)||For flow constrictions, the bridge deck factor.
|-
| FC_Width_Factor (only if the model has flow constrictions)||For flow constrictions, the flow width factor.
|-
| Domain_Index||The index of the model domain. This is the order with <tt><font color="blue">Start 2D Domain </font><font color="red">== </font><Domain Name></tt> commands appears in the TCF control file. For a single domain model this will be 1.
|}
|}
:'''Example _uvpt_check attribute table (using Quadtree):'''
:'''Example _uvpt_check attribute table (using Quadtree):'''
:[[File:]]
:[[File:2d_uvpt_Quad_attribute_table_01.png]]
<br>


== Features ==
== Features ==

Latest revision as of 09:43, 28 October 2024

Introduction

This GIS file contains information about the cell sides (U and V points).

Attributes of _uvpt_check

General Attributes

Attribute Name Attribute Description
n Row number in the TUFLOW domain.
m Column number in the TUFLOW domain.
Type Zpt type (U or V).
Init_Vel Initial Velocity.
Mannings_n (default)
Chezy_Coeff
Mannings_M
Roughness coefficient.
FLC Additional form loss applied.
WrF Weir factor.
FC_Depth_to_Lid (only if the model has flow constrictions) For flow constrictions, the depth to the obvert.
FC_BD_Factor (only if the model has flow constrictions) For flow constrictions, the bridge deck factor.
FC_Width_Factor (only if the model has flow constrictions) For flow constrictions, the flow width factor.
Domain_Index The index of the model domain. This is the order with Start 2D Domain == <Domain Name> commands appears in the TCF control file. For a single domain model this will be 1.
Example _uvpt_check attribute table:


Attributes when using quadtree

Attribute Name Attribute Description
qpc_id The quadtree cell ID.
Type Zpt type (U or V).
Init_Vel Initial Velocity.
Mannings_n (default)
Chezy_Coeff
Mannings_M
Roughness coefficient.
Example _uvpt_check attribute table (using Quadtree):


Features

The image below shows the _uvpt_check styled by the Manning's n value. Note if using depth varying varying roughness the Material ID attribute in the _grd_check file may be preferred.




Up
TUFLOW Check Files