TUFLOW Message 2024: Difference between revisions
Content deleted Content added
Steph.dufour (talk | contribs) No edit summary |
No edit summary |
||
| (3 intermediate revisions by 2 users not shown) | |||
Line 7:
Check that the "CN" line finishes at a 1D node. In the example below, a single line has been digitised from the HX line to the HX line. Whilst it is snapped to the 1D node, it does not terminate there and therefore will cause Error 2024 to be generated.<br>
Note that the direction the "CN" line is digitised is not important.<br>
Check the 2d_bc and 1n_nwk layers have the same projection.<br>
[[File:Error 2024.PNG|500px]]
<br><br>
In the next image, this line has been split at the 1D node and the issue is resolved.<br>
[[File:Error 2024 fix.PNG|500px]]
'''Please note:''' If the model is a Flood Modeller-TUFLOW (FM-TUFLOW) model and you are trying to run as a TUFLOW only model, this is a common error message as TUFLOW cannot find the external 1D nodes. For more details on running a FM-TUFLOW model please visit the WIKI page below: [https://wiki.tuflow.com/Running_linked_Flood_Modeller_-_TUFLOW_Models Running linked Flood modeller - TUFLOW Models]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
}}
| |||