− | + | Contains information on the cell sides (U and V points) that have a flow constriction shape object applied. This contains information on the processed elevations, blockages and form loss values applied at the cell side. | |
+ | <br> | ||
+ | |||
+ | '''Attributes of fcsh_uvpt'''<br> | ||
+ | {| align="center" class="wikitable" width="75%" | ||
+ | ! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name | ||
+ | ! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description | ||
+ | |- | ||
+ | | FC_Type||The flow constriction type as described in the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u>. | ||
+ | |- | ||
+ | | Z_Bed||The ground level of the z point. | ||
+ | |- | ||
+ | | Obvert_or_BC_H_or_FD_Depth|| This attribute is dependent on the FC type:<br> | ||
+ | * For a blank flow or "BD" constriction type this is the structure obvert. Above this elevation there is no additional flow area. | ||
+ | * For a "BC" constriction type this is the height of the box culvert. | ||
+ | * For a "FD" constriction type this is the depth of the object. | ||
+ | |- | ||
+ | | pBlockage||The percentage (%) blockage of below the deck level, above this the blockage is 100%. | ||
+ | |- | ||
+ | | FLC_below_Obvert||The '''F'''orm '''L'''oss '''C'''oefficient below the structure obvert. | ||
+ | |- | ||
+ | | FLC_above_Obvert||The '''F'''orm '''L'''oss '''C'''oefficient above the structure obvert. | ||
+ | |- | ||
+ | | BC_n_or_BD_n||For the "BC" or "BD" type constrictions this is the n attribute. | ||
+ | |- | ||
+ | | BC_Width||For a "BC" type this is the box culvert width. | ||
+ | |- | ||
+ | | Source||This is the source GIS layer which contains the flow constriction shape. | ||
+ | |} | ||
+ | |||
+ | |||
+ | {{Tips Navigation | ||
+ | |uplink=[[TUFLOW_Check_Files | TUFLOW Check Files]] | ||
+ | }} |
Latest revision as of 09:53, 23 September 2024
Contains information on the cell sides (U and V points) that have a flow constriction shape object applied. This contains information on the processed elevations, blockages and form loss values applied at the cell side.
Attributes of fcsh_uvpt
Attribute Name | Attribute Description |
---|---|
FC_Type | The flow constriction type as described in the TUFLOW Manual. |
Z_Bed | The ground level of the z point. |
Obvert_or_BC_H_or_FD_Depth | This attribute is dependent on the FC type:
|
pBlockage | The percentage (%) blockage of below the deck level, above this the blockage is 100%. |
FLC_below_Obvert | The Form Loss Coefficient below the structure obvert. |
FLC_above_Obvert | The Form Loss Coefficient above the structure obvert. |
BC_n_or_BD_n | For the "BC" or "BD" type constrictions this is the n attribute. |
BC_Width | For a "BC" type this is the box culvert width. |
Source | This is the source GIS layer which contains the flow constriction shape. |