Difference between revisions of "TUFLOW Message 2237"

From Tuflow
Jump to navigation Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=WARNING 2237 - ZPT XF file precision conflict. Switching to GIS layer. |alt_msg=NA |type=WARNING |message_desc=???? |suggestions=???? |discu...')
 
 
(5 intermediate revisions by 3 users not shown)
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[WARNING]]
 
|type=[[WARNING]]
|message_desc=????
+
|message_desc=The binary dump of input layers (XF files), is written on single and double precision version depending on the executable used (refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more information). These should be seperate files.  The the single precision (4-byte real numbers) should have a .xf4 extension, while the double precision (8-byte real numbers) has .xf8 extension.  For example:<br>
|suggestions=????
+
* 2d_zpt_M01_5m_003.mid.xf4 (single precision)<br>
|discussion_page=* [[Talk:TUFLOW Message 2237|Discuss Message 2237]]
+
* 2d_zpt_M01_5m_003.mid.xf8 (double precision)<br>
|link3=''
+
 
|link4=''
+
Message 2237 has occurred because the precision of the XF file conflicts, with the model.  TUFLOW reads in the correct precision when simulating, a double precision version of TUFLOW will look for .xf8 files and ignore .xf4 files.  This message can occur if a XF file has been renamed.
|prelink=[[TUFLOW_Message_2236|Message 2236]]
+
|suggestions=TUFLOW has defaulted to the original GIS files and ignored the XF files.  Delete XF file to have TUFLOW create new version.
 +
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2308|Message 2308]]
 
 
}}
 
}}

Latest revision as of 09:22, 23 September 2024

TUFLOW Message
WARNING 2237 - ZPT XF file precision conflict. Switching to GIS layer.

Alternate Message
NA

Message Type
WARNING

Description
The binary dump of input layers (XF files), is written on single and double precision version depending on the executable used (refer to the TUFLOW Manual for more information). These should be seperate files. The the single precision (4-byte real numbers) should have a .xf4 extension, while the double precision (8-byte real numbers) has .xf8 extension. For example:

  • 2d_zpt_M01_5m_003.mid.xf4 (single precision)
  • 2d_zpt_M01_5m_003.mid.xf8 (double precision)

Message 2237 has occurred because the precision of the XF file conflicts, with the model. TUFLOW reads in the correct precision when simulating, a double precision version of TUFLOW will look for .xf8 files and ignore .xf4 files. This message can occur if a XF file has been renamed.

Suggestions
TUFLOW has defaulted to the original GIS files and ignored the XF files. Delete XF file to have TUFLOW create new version.


Up