|type=[[ERROR]] | |type=[[ERROR]] | ||
|message_desc=Could not find a 1D node snapped to 2d_bc connection (CN) line. | |message_desc=Could not find a 1D node snapped to 2d_bc connection (CN) line. | ||
− | |suggestions=Check snapping and location of 2d_bc "CN" type object. This should connect a 1D node to a 2D boundary condition, e.g. "HX" or "SX" type connection. | + | |suggestions=Check snapping and location of 2d_bc "CN" type object. This should connect a 1D node to a 2D boundary condition, e.g. "HX" or "SX" type connection. The messages.mif or messages_P.shp file will contain the location of the error. |
|discussion_page=* [[Talk:TUFLOW Message 2024|Discuss Message 2024]] | |discussion_page=* [[Talk:TUFLOW Message 2024|Discuss Message 2024]] | ||
|link3='' | |link3='' |
Revision as of 10:04, 9 July 2012
TUFLOW Message
ERROR 2024 - Could not find a 1D node snapped to CN line.
Alternate Message
NA
Message Type
ERROR
Description
Could not find a 1D node snapped to 2d_bc connection (CN) line.
Suggestions
Check snapping and location of 2d_bc "CN" type object. This should connect a 1D node to a 2D boundary condition, e.g. "HX" or "SX" type connection. The messages.mif or messages_P.shp file will contain the location of the error.