TUFLOW Message 1286: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
| Line 5: | Line 5: | ||
|message_desc= Flow from 1D QT region can't be applied to a H boundary or a 2D SX link. |
|message_desc= Flow from 1D QT region can't be applied to a H boundary or a 2D SX link. |
||
|suggestions=Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes. |
|suggestions=Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes. |
||
|discussion_page=* [[Talk:TUFLOW Message 1286|Discuss Message 1286]] |
|||
|link3='' |
|||
|link4='' |
|||
|prelink=[[TUFLOW_Message_1285|Message 1285]] |
|prelink=[[TUFLOW_Message_1285|Message 1285]] |
||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
||
Revision as of 14:44, 5 July 2022
TUFLOW Message
ERROR 1286 - All 1D nodes within 1D QT region to be assigned a flow are a H boundary or a 2D SX link.
Alternate Message
NA
Message Type
ERROR
Description
Flow from 1D QT region can't be applied to a H boundary or a 2D SX link.
Suggestions
Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes.