== Summary ==
The Green-Ampt infiltration model is one of the available infiltration models within TUFLOW. There is a wide range of literature on Green-Ampt applications and some suggested parameter values for particular soil types, albeit mostly soil types from the US. The 3 main Green-Ampt parameters have been tested to show the sensitivity of model outputs to the values as well as the variation in initial moisture. The results show that the model is relatively insensitive to the porosity value and suction head parameter. However, the outputs do show significant variations in runoff volume due to variations in both hydraulic conductivity. As part of any calibration exercise it is suggested that it is the hydraulic conductivity, in conjunction with the initial moisture content, which would be the parameters that are most focused on. The hydraulic conductivity appears to affect the runoff volume throughout the event whereas the initial soil moisture has a limited impact at the beginning of the event before soils become saturated and results converge.<br>
==Acknowledgements==
The Plynlimon model contains data supplied by Natural Environment Research Council. The Plynlimon observed rain gauge and flow data was provided by the Centre of Hydrology, Bangor. The model uses LiDAR data which is public sector information licensed under the Open Government Licence v3.0.
| |||