TUFLOW Version Backward Compatibility: Difference between revisions
Content deleted Content added
No edit summary |
No edit summary |
||
Line 189:
|-
| Uses a new set of defaults for a number of commands.
| The new defaults will produce different results. For established models run using the 2005-05-XX builds, use <font color="blue"><tt>Defaults </tt></font> <font color="red"><tt>== </tt></font><tt> PRE 2006-06-AA</
|-
| <font color="blue"><tt>Cell Wet/Dry Depth </tt></font> <font color="red"><tt>== </tt></font><tt> 0.002</
| The most pronounced effect of the shallower wet/dry depths is likely to occur in areas that are still filling at the flood peak, such as behind a levee that is only just overtopped. The shallower wet/dry depths provides a greater flow depth for a longer period over the levee.
|-
| <font color="blue"><tt>Adjust Head at ESTRY Interface </tt></font> <font color="red"><tt>==
| Usually does not have a major influence on results except where very high velocities occur.
|-
| |||