QGIS SWMM Junctions Set Attributes: Difference between revisions
Content deleted Content added
Line 33:
<li>'''General Options:'''
:*'''Maximum Depth Option (Ymax):'''
::*Set to 0.0: Initializes the Ymax for all junction nodes to 0.0. This option may be overwritten
::*Leave as is: Leaves the Ymax value as is for all junction nodes. This option only applies
:*'''Nodes receiving subcatchment flows option (if connected to 2D):'''
::*Based on options selected below:
::*Set Apond = 0.0; Ysur = 0.0 (overwrites options below): Forces subcatchment outlets to use 0.0 for Ysur and Apond (turns off ponding). When ponding is off, node surcharging is reported as 'flooding' to SWMM and is immediately transferred to the 2D domain.
<li>'''Nodes connected to the 2D without inlets (through embankment culvert):'''
:*'''Ysur:''' Sets the surcharge at nodes connected to the 2D with inlets. Recommended value is 0.0.
:*'''Apond:'''
<li>'''Nodes connected to 2D with inlets (underground pipe network):'''
:*'''Maximum depth (Ymax) option (overwrites general setting):'''
::*Set to inlet elevation - node elevation: Sets the Ymax value to the inlet elevation minus the node elevation.
::*Use global option: Sets the Ymax value based on the
:*'''Ysur:''' Set to 0.0 if using ponding. Otherwise, set to higher than expected depths to prevent flooding.
:*'''Area of ponding:''' Set to the
<li>'''Nodes without a 2D connection (underground pipe network):''' When a node is not connected to the 2D, flood losses will be lost from the model resulting in mass losses and inaccurate results. To prevent this, allow ponding (option 1) or make the surcharge depth high (option 2).
:*Option 1:
| |||