TUFLOW Message 2024: Difference between revisions

Content deleted Content added
No edit summary
No edit summary
Line 4:
|type=[[ERROR]]
|message_desc=Could not find a 1D node snapped to 2d_bc connection (CN) line.
|suggestions=Check snapping and location of 2d_bc "CN" type object. This should connect a 1D node to a 2D boundary condition, e.g. "HX" or "SX" type connection. The messages.mif or messages_P.shp file will contain the location of the error.<br>
Check that the "CN" line finishes at a 1D node. In the example below, a single line has been digitised from the HX line to the HX line. Whilst it is snapped to the 1D node, it does not terminate there.<br>
[[File:Error 2024.PNG|500px]]
<br><br>
In the next image, this line has been split at the 1D node and the issue is resolved.<br>
[[File:Error 2024 fix.PNG|500px]]
|discussion_page=* [[Talk:TUFLOW Message 2024|Discuss Message 2024]]
|link3=''