Check Files 2d uvpt: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
|||
Line 34: | Line 34: | ||
=== |
=== Attributes when using quadtree === |
||
{| align="center" class="wikitable" width="75%" |
{| align="center" class="wikitable" width="75%" |
||
! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name |
! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name |
||
! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description |
! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description |
||
|- |
|- |
||
| qpc_id||The quadtree cell ID. |
|||
| n||Row number in the TUFLOW domain. |
|||
|- |
|||
| m||Column number in the TUFLOW domain. |
|||
|- |
|- |
||
| Type||Zpt type (U or V). |
| Type||Zpt type (U or V). |
||
Line 48: | Line 46: | ||
|- |
|- |
||
| Mannings_n (default)<br>Chezy_Coeff<br>Mannings_M ||Roughness coefficient. |
| Mannings_n (default)<br>Chezy_Coeff<br>Mannings_M ||Roughness coefficient. |
||
|- |
|||
| FLC||Additional form loss applied. |
|||
|- |
|||
| WrF||Weir factor. |
|||
|- |
|- |
||
| FC_Depth_to_Lid (only if the model has flow constrictions)||For flow constrictions, the depth to the obvert. |
| FC_Depth_to_Lid (only if the model has flow constrictions)||For flow constrictions, the depth to the obvert. |
||
Line 58: | Line 52: | ||
|- |
|- |
||
| FC_Width_Factor (only if the model has flow constrictions)||For flow constrictions, the flow width factor. |
| FC_Width_Factor (only if the model has flow constrictions)||For flow constrictions, the flow width factor. |
||
|- |
|||
| Domain_Index||The index of the model domain. This is the order with <tt><font color="blue">Start 2D Domain </font><font color="red">== </font><Domain Name></tt> commands appears in the TCF control file. For a single domain model this will be 1. |
|||
|} |
|||
:'''Example _uvpt_check attribute table (using SGS):''' |
|||
:[[File:]] |
|||
=== Quadtree Specific Attributes === |
|||
{| align="center" class="wikitable" width="75%" |
|||
! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name |
|||
! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description |
|||
|- |
|||
| n||Row number in the TUFLOW domain. |
|||
|- |
|||
| m||Column number in the TUFLOW domain. |
|||
|- |
|||
| Type||Zpt type (U or V). |
|||
|- |
|||
| Init_Vel||Initial Velocity. |
|||
|- |
|||
| Mannings_n (default)<br>Chezy_Coeff<br>Mannings_M ||Roughness coefficient. |
|||
|- |
|||
| FLC||Additional form loss applied. |
|||
|- |
|||
| WrF||Weir factor. |
|||
|- |
|||
| FC_Depth_to_Lid (only if the model has flow constrictions)||For flow constrictions, the depth to the obvert. |
|||
|- |
|||
| FC_BD_Factor (only if the model has flow constrictions)||For flow constrictions, the bridge deck factor. |
|||
|- |
|||
| FC_Width_Factor (only if the model has flow constrictions)||For flow constrictions, the flow width factor. |
|||
|- |
|||
| Domain_Index||The index of the model domain. This is the order with <tt><font color="blue">Start 2D Domain </font><font color="red">== </font><Domain Name></tt> commands appears in the TCF control file. For a single domain model this will be 1. |
|||
|} |
|} |
||
:'''Example _uvpt_check attribute table (using Quadtree):''' |
:'''Example _uvpt_check attribute table (using Quadtree):''' |
Revision as of 09:13, 28 October 2024
Introduction
This GIS file contains information about the cell sides (U and V points).
Attributes of _uvpt_check
General Attributes
Attribute Name | Attribute Description |
---|---|
n | Row number in the TUFLOW domain. |
m | Column number in the TUFLOW domain. |
Type | Zpt type (U or V). |
Init_Vel | Initial Velocity. |
Mannings_n (default) Chezy_Coeff Mannings_M |
Roughness coefficient. |
FLC | Additional form loss applied. |
WrF | Weir factor. |
FC_Depth_to_Lid (only if the model has flow constrictions) | For flow constrictions, the depth to the obvert. |
FC_BD_Factor (only if the model has flow constrictions) | For flow constrictions, the bridge deck factor. |
FC_Width_Factor (only if the model has flow constrictions) | For flow constrictions, the flow width factor. |
Domain_Index | The index of the model domain. This is the order with Start 2D Domain == <Domain Name> commands appears in the TCF control file. For a single domain model this will be 1. |
- Example _uvpt_check attribute table:
- [[File:]]
Attributes when using quadtree
Attribute Name | Attribute Description |
---|---|
qpc_id | The quadtree cell ID. |
Type | Zpt type (U or V). |
Init_Vel | Initial Velocity. |
Mannings_n (default) Chezy_Coeff Mannings_M |
Roughness coefficient. |
FC_Depth_to_Lid (only if the model has flow constrictions) | For flow constrictions, the depth to the obvert. |
FC_BD_Factor (only if the model has flow constrictions) | For flow constrictions, the bridge deck factor. |
FC_Width_Factor (only if the model has flow constrictions) | For flow constrictions, the flow width factor. |
- Example _uvpt_check attribute table (using Quadtree):
- [[File:]]
Features
The image below shows the _uvpt_check styled by the Manning's n value. Note if using depth varying varying roughness the Material ID attribute in the _grd_check file may be preferred.
Up |
---|
![]() |