Difference between revisions of "TUFLOW Message 2016"

From Tuflow
Jump to navigation Jump to search
Line 4: Line 4:
 
|type=[[ERROR]]
 
|type=[[ERROR]]
 
|message_desc=Unrecognisable 2D connection specified for pit or manhole.
 
|message_desc=Unrecognisable 2D connection specified for pit or manhole.
|suggestions=????
+
|suggestions=The Conn_2D attribute in the 1d_nwk can be used to create a 2D connection.  Valid options are:
 +
* SX
 +
* SXZ
 +
* SXL
 +
* SXG
 +
* SXS
 +
For more information on these please see Section 4.5.1.3 and Table 4.14 of the 2010 TUFLOW manual.
 
|discussion_page=* [[Talk:TUFLOW Message 2016|Discuss Message 2016]]
 
|discussion_page=* [[Talk:TUFLOW Message 2016|Discuss Message 2016]]
 
|link3=''
 
|link3=''

Revision as of 13:00, 3 July 2012

TUFLOW Message
ERROR 2016 - Unrecognisable 2D connection specified for pit or manhole.

Alternate Message
NA

Message Type
ERROR

Description
Unrecognisable 2D connection specified for pit or manhole.

Suggestions
The Conn_2D attribute in the 1d_nwk can be used to create a 2D connection. Valid options are:

  • SX
  • SXZ
  • SXL
  • SXG
  • SXS

For more information on these please see Section 4.5.1.3 and Table 4.14 of the 2010 TUFLOW manual.


Up
Go-up.png 2xxx Messages