Difference between revisions of "TUFLOW Message 2036"
Jump to navigation
Jump to search
Line 4: | Line 4: | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
|message_desc=Trying to apply a source flow (S) boundary to a 2D cell already assigned a link or a water level (H) or lateral flow (Q) boundary. | |message_desc=Trying to apply a source flow (S) boundary to a 2D cell already assigned a link or a water level (H) or lateral flow (Q) boundary. | ||
− | |suggestions= | + | |suggestions=Seperate incompatible boundary types. |
|discussion_page=* [[Talk:TUFLOW Message 2036|Discuss Message 2036]] | |discussion_page=* [[Talk:TUFLOW Message 2036|Discuss Message 2036]] | ||
|link3='' | |link3='' |
Revision as of 17:00, 6 February 2011
TUFLOW Message
ERROR 2036 - Trying to apply a S boundary to a 2D cell already assigned a link or a H or Q boundary.
Alternate Message
NA
Message Type
ERROR
Description
Trying to apply a source flow (S) boundary to a 2D cell already assigned a link or a water level (H) or lateral flow (Q) boundary.
Suggestions
Seperate incompatible boundary types.
Up |
---|
2xxx Messages |