Difference between revisions of "TUFLOW Message 2071"

From Tuflow
Jump to navigation Jump to search
Line 4: Line 4:
 
|type=[[WARNING]]
 
|type=[[WARNING]]
 
|message_desc=The Cell Side Wet/Dry Depth is greater than the Cell Wet/Dry Depth.
 
|message_desc=The Cell Side Wet/Dry Depth is greater than the Cell Wet/Dry Depth.
|suggestions=????
+
|suggestions=As of Build 2008 08 AA, this command has been disabled and the cell side wet/dry depth is always set to half the Cell Wet/Dry Depth value.  This was implemented to prevent mass errors that sometimes occurred due to inappropriate cell side wet/dry depths being used.  Does not apply if Defaults == PRE 2008-08.  The default value of  0.001m remains unchanged.
 
|discussion_page=* [[Talk:TUFLOW Message 2071|Discuss Message 2071]]
 
|discussion_page=* [[Talk:TUFLOW Message 2071|Discuss Message 2071]]
 
|link3=''
 
|link3=''

Revision as of 19:06, 14 February 2011

TUFLOW Message
WARNING 2071 - The Cell Side Wet/Dry Depth is greater than the Cell Wet/Dry Depth.

Alternate Message
NA

Message Type
WARNING

Description
The Cell Side Wet/Dry Depth is greater than the Cell Wet/Dry Depth.

Suggestions
As of Build 2008 08 AA, this command has been disabled and the cell side wet/dry depth is always set to half the Cell Wet/Dry Depth value. This was implemented to prevent mass errors that sometimes occurred due to inappropriate cell side wet/dry depths being used. Does not apply if Defaults == PRE 2008-08. The default value of 0.001m remains unchanged.


Up
Go-up.png 2xxx Messages