Line 3: Line 3:
 
|alt_msg=ERROR 2194 - Column 1 values not ascending in ",a," table.
 
|alt_msg=ERROR 2194 - Column 1 values not ascending in ",a," table.
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=Column 1 values not ascending in a boundary condition table.  Table data is output to the .tlf file and console.
+
|message_desc=Column 1 values not ascending in a boundary condition table.  Table data is output to the .tlf file and console. For a Head-Time the first column is the time data, time values should be unique and in ascending order. The same applies to all boundary condition types.  For a HQ (stage-discharge, or rating curve) the height values should be increasing.  
|suggestions=????
+
|suggestions=Check data, remove duplicate values and sort by first column.
 
|discussion_page=* [[Talk:TUFLOW Message 2194|Discuss Message 2194]]
 
|discussion_page=* [[Talk:TUFLOW Message 2194|Discuss Message 2194]]
 
|link3=''
 
|link3=''

Revision as of 10:57, 18 February 2011

TUFLOW Message
ERROR 2194 - Column 1 values not ascending in ",a," table

Alternate Message
ERROR 2194 - Column 1 values not ascending in ",a," table.

Message Type
ERROR

Description
Column 1 values not ascending in a boundary condition table. Table data is output to the .tlf file and console. For a Head-Time the first column is the time data, time values should be unique and in ascending order. The same applies to all boundary condition types. For a HQ (stage-discharge, or rating curve) the height values should be increasing.

Suggestions
Check data, remove duplicate values and sort by first column.


Up
Go-up.png 2xxx Messages