TUFLOW Message 1262: Difference between revisions
Content deleted Content added
No edit summary |
No edit summary |
||
Line 3:
|alt_msg=NA
|type=[[WARNING]]
|message_desc=Manning's n value assigned to channel, is outside normal range.
|suggestions=Check Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process). This can occur if a the multiplication value is set to a typical Mannings value (e.g. 0.04) and materials are defined in the XZM cross-section. In this case the Mannings n value may become 0.04 x 0.04 = 0.0016!
|discussion_page=* [[Talk:TUFLOW Message 1262|Discuss Message 1262]]
|link3=''
|