Difference between revisions of "TUFLOW Message 2024"
Jump to navigation
Jump to search
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc=Could not find a 1D node snapped to connection (CN) line. | + | |message_desc=Could not find a 1D node snapped to 2d_bc connection (CN) line. |
− | |suggestions= | + | |suggestions=Check snapping and location of 2d_bc "CN" type object. This should connect a 1D node to a 2D boundary condition, e.g. "HX" or "SX" type connection. |
|discussion_page=* [[Talk:TUFLOW Message 2024|Discuss Message 2024]] | |discussion_page=* [[Talk:TUFLOW Message 2024|Discuss Message 2024]] | ||
|link3='' | |link3='' |
Revision as of 16:27, 6 February 2011
TUFLOW Message
ERROR 2024 - Could not find a 1D node snapped to CN line.
Alternate Message
NA
Message Type
ERROR
Description
Could not find a 1D node snapped to 2d_bc connection (CN) line.
Suggestions
Check snapping and location of 2d_bc "CN" type object. This should connect a 1D node to a 2D boundary condition, e.g. "HX" or "SX" type connection.
Up |
---|
2xxx Messages |