TUFLOW Message 2071: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
| Line 4: | Line 4: | ||
|type=[[WARNING]] |
|type=[[WARNING]] |
||
|message_desc=The Cell Side Wet/Dry Depth is greater than the Cell Wet/Dry Depth. |
|message_desc=The Cell Side Wet/Dry Depth is greater than the Cell Wet/Dry Depth. |
||
|suggestions=As of Build 2008 08 AA, this command has been disabled and the cell side wet/dry depth is always set to half the Cell Wet/Dry Depth value. This was implemented to prevent mass errors that sometimes occurred due to inappropriate cell side wet/dry depths being used. Does not apply if Defaults == PRE 2008-08. The default value of 0.001m remains unchanged. |
|||
|suggestions=???? |
|||
|discussion_page=* [[Talk:TUFLOW Message 2071|Discuss Message 2071]] |
|discussion_page=* [[Talk:TUFLOW Message 2071|Discuss Message 2071]] |
||
|link3='' |
|link3='' |
||
Revision as of 19:06, 14 February 2011
TUFLOW Message
WARNING 2071 - The Cell Side Wet/Dry Depth is greater than the Cell Wet/Dry Depth.
Alternate Message
NA
Message Type
WARNING
Description
The Cell Side Wet/Dry Depth is greater than the Cell Wet/Dry Depth.
Suggestions
As of Build 2008 08 AA, this command has been disabled and the cell side wet/dry depth is always set to half the Cell Wet/Dry Depth value. This was implemented to prevent mass errors that sometimes occurred due to inappropriate cell side wet/dry depths being used. Does not apply if Defaults == PRE 2008-08. The default value of 0.001m remains unchanged.
| Up |
|---|