Line 4: | Line 4: | ||
|type=[[WARNING]] | |type=[[WARNING]] | ||
|message_desc=The Cell Side Wet/Dry Depth is greater than the Cell Wet/Dry Depth. | |message_desc=The Cell Side Wet/Dry Depth is greater than the Cell Wet/Dry Depth. | ||
− | |suggestions= | + | |suggestions=As of Build 2008 08 AA, this command has been disabled and the cell side wet/dry depth is always set to half the Cell Wet/Dry Depth value. This was implemented to prevent mass errors that sometimes occurred due to inappropriate cell side wet/dry depths being used. Does not apply if Defaults == PRE 2008-08. The default value of 0.001m remains unchanged. |
|discussion_page=* [[Talk:TUFLOW Message 2071|Discuss Message 2071]] | |discussion_page=* [[Talk:TUFLOW Message 2071|Discuss Message 2071]] | ||
|link3='' | |link3='' |
Revision as of 19:06, 14 February 2011
TUFLOW Message
WARNING 2071 - The Cell Side Wet/Dry Depth is greater than the Cell Wet/Dry Depth.
Alternate Message
NA
Message Type
WARNING
Description
The Cell Side Wet/Dry Depth is greater than the Cell Wet/Dry Depth.
Suggestions
As of Build 2008 08 AA, this command has been disabled and the cell side wet/dry depth is always set to half the Cell Wet/Dry Depth value. This was implemented to prevent mass errors that sometimes occurred due to inappropriate cell side wet/dry depths being used. Does not apply if Defaults == PRE 2008-08. The default value of 0.001m remains unchanged.