1D Pumps: Difference between revisions
Content deleted Content added
Rohan.king (talk | contribs) |
Rohan.king (talk | contribs) |
||
Line 68:
The use of pump curves within TUFLOW requires a 2015 or later build. The setup of the Depth Discharge database for a pump curve is similar to reading in inflow hydrographs, hyetographs etc, that is; a source .csv, and the two corresponding headings within the 3rd and 4th column. <br>
[[File:depth-discharge_pump.PNG |border|500px]] <br>
Once you have your manufacturer curve for your given pump it is now necessary to create the curve .csv for TUFLOW to read in. The manufacturer specifications will need to be translated into a total head vs pump rate chart. Although reading in the depth discharge database is the same process as other boundary conditions within TUFLOW, the curve itself is fundamentally different as you no longer need to start the csv file with 0,0. If the curve did start at 0,0 this would not make sense because at a total head difference of 0m the pump should effectively be operating at peak performance so the flow rate would be greater than
<br>
[[File:Pump_curve_csv_example.png|border|600px]] <br>
| |||