Difference between revisions of "TUFLOW Message 2056"

From Tuflow
Jump to navigation Jump to search
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=The number of boundary conditions requested is different to the number found.  This message should only occur for old fixed field format TUFLOW models.  If the model is not an old fixed field format please contact <font color="blue>support@tuflow.com</font> and attach the .tlf file.
+
|message_desc=The number of boundary conditions requested is different to the number found.  This message should only occur for old fixed field format TUFLOW models.  If the model is not an old fixed field format, and the latest release is used, please contact <font color="blue>support@tuflow.com</font> and attach the .tlf file.
 
|suggestions=Redundant, as of the 2010 release of TUFLOW, fixed field format models are no longer recognised.<br>
 
|suggestions=Redundant, as of the 2010 release of TUFLOW, fixed field format models are no longer recognised.<br>
 
For builds from 2010 to 2013 this error could spuriously occur if a 1d_bc layer was being read into the 2D boundary control file (.tbc).  As of the 2016 version of TUFLOW, <u>[[TUFLOW Message 2340|ERROR 2340]]</u> will be returned instead.  See this message for more information.
 
For builds from 2010 to 2013 this error could spuriously occur if a 1d_bc layer was being read into the 2D boundary control file (.tbc).  As of the 2016 version of TUFLOW, <u>[[TUFLOW Message 2340|ERROR 2340]]</u> will be returned instead.  See this message for more information.

Revision as of 11:32, 19 July 2022

TUFLOW Message
ERROR 2056 - Requested "a" BCs, Read "b"

Alternate Message
NA

Message Type
ERROR

Description
The number of boundary conditions requested is different to the number found. This message should only occur for old fixed field format TUFLOW models. If the model is not an old fixed field format, and the latest release is used, please contact support@tuflow.com and attach the .tlf file.

Suggestions
Redundant, as of the 2010 release of TUFLOW, fixed field format models are no longer recognised.
For builds from 2010 to 2013 this error could spuriously occur if a 1d_bc layer was being read into the 2D boundary control file (.tbc). As of the 2016 version of TUFLOW, ERROR 2340 will be returned instead. See this message for more information.


Up
Go-up.png 2xxx Messages