Difference between revisions of "TUFLOW Message 1286"

From Tuflow
Jump to navigation Jump to search
 
Line 6: Line 6:
 
|suggestions=Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes.
 
|suggestions=Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes.
  
|prelink=[[TUFLOW_Message_1285|Message 1285]]
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1287|Message 1287]]
 
 
}}
 
}}

Latest revision as of 10:21, 23 December 2022

TUFLOW Message
ERROR 1286 - All 1D nodes within 1D QT region to be assigned a flow are a H boundary or a 2D SX link.

Alternate Message
NA

Message Type
ERROR

Description
Flow from 1D QT region can't be applied to a H boundary or a 2D SX link.

Suggestions
Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes.


Up
Go-up.png 1xxx Messages