Revision as of 09:16, 3 March 2023
TUFLOW Message 
ERROR 2541 - SX polygon selects no cells.
Alternate Message 
CHECK 2541 - SX polygon selects no cells, centroid used.
Description 
No cell centre falls within SX polygon. If the message type is "CHECK", the SA polygon centroid still falls within the active model domain and the centroid will be used to choose the nearest cell as a connection between 1D and 2D. If the message type is "ERROR", the SA polygon centroid falls outside the model and the TUFLOW will exit with error.
Suggestions 
Review the SX polygon size and check if it is located inside the active model domain.
| Up | 
|---|
|  2xxx Messages |