Difference between revisions of "TUFLOW Message 2541"

From Tuflow
Jump to navigation Jump to search
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
 
|tuflow_message=ERROR 2541 - SX polygon selects no cells.
 
|tuflow_message=ERROR 2541 - SX polygon selects no cells.
|alt_msg=CHECK 2541 - SX polygon selects no cells, centroid used.
+
|alt_msg=CHECK 2541 - SX polygon selects no cells, centroid used.<br>
|alt_msg=CHECK 2541 - SX polyline selects no cells, using midpoint.
+
CHECK 2541 - SX polyline selects no cells, using midpoint.
 
|type=[[ERROR]] [[CHECK]]
 
|type=[[ERROR]] [[CHECK]]
 
|message_desc=No cell centre falls within SX polygon. If the message type is "CHECK", the SA polygon centroid still falls within the active model domain and the centroid will be used to choose the nearest cell as a connection between 1D and 2D. If the message type is "ERROR", the SA polygon centroid falls outside the model and the TUFLOW will exit with error. If CHECK 2541 appears for a polyline, the 2D cell in which the midpoint of the SX line falls within will be used as the connection location.  
 
|message_desc=No cell centre falls within SX polygon. If the message type is "CHECK", the SA polygon centroid still falls within the active model domain and the centroid will be used to choose the nearest cell as a connection between 1D and 2D. If the message type is "ERROR", the SA polygon centroid falls outside the model and the TUFLOW will exit with error. If CHECK 2541 appears for a polyline, the 2D cell in which the midpoint of the SX line falls within will be used as the connection location.  

Revision as of 21:24, 19 February 2024

TUFLOW Message
ERROR 2541 - SX polygon selects no cells.

Alternate Message
CHECK 2541 - SX polygon selects no cells, centroid used.
CHECK 2541 - SX polyline selects no cells, using midpoint.

Message Type
ERROR CHECK

Description
No cell centre falls within SX polygon. If the message type is "CHECK", the SA polygon centroid still falls within the active model domain and the centroid will be used to choose the nearest cell as a connection between 1D and 2D. If the message type is "ERROR", the SA polygon centroid falls outside the model and the TUFLOW will exit with error. If CHECK 2541 appears for a polyline, the 2D cell in which the midpoint of the SX line falls within will be used as the connection location.

Suggestions
Review the SX polygon size and check if it is located inside the active model domain.


Up
Go-up.png 2xxx Messages