TUFLOW CATCH Tutorial M02 Results QGIS: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
Line 1: Line 1:
<font color="red"><font size=18>Page Under Construction</font></font>
<font color="red"><font size=18>Page Under Construction</font></font>
==Introduction==
== Introduction ==
Use the TUFLOW CATCH plugin to create a TUFLOW CATCH JSON file to review the TUFLOW HPC and TUFLOW FV results simultaneously.
Review the TUFLOW CATCH interventions output summary. Review how the treatment devices are removing pollutants.


Refer to <u>[[TUFLOW_CATCH_Tutorial_M01_Results_QGIS | TUFLOW CATCH Tutorial 1]]</u> for information on timeseries outputs.
Refer to <u>[[TUFLOW_CATCH_Tutorial_M01_Results_QGIS | TUFLOW CATCH Tutorial 1]]</u> for information on timeseries outputs.


== TUFLOW CATCH Interventions Output Summary ==
==Create JSON File==
Review the interventions summary:
Create a TUFLOW CATCH JSON file:
<ol>
<ol>
<li> In Windows File Explorer, navigate to the '''TUFLOWCatch\results''' folder and open '''TC02_001_catchment_hydraulic_intervention_summary.csv'''.
<li> Go to Processing > Toolbox from the top drop down menu options to open the Processing Toolbox.
<li> This file contains final cumulative flows, masses entering and masses removed for all intervention devices and pollutants. All output masses are in grams.<br>
<li> Go to TUFLOW Catch in the processing tool list and select <font color=red> create page?</font> <u>'Create TUFLOW Catch JSON'</u>. This opens the dialog shown below.
<br>
* Results: Click '...', and select 'Add File(s)...'. Navigate to the '''TUFLOWCatch\results''' folder and select '''TC02_001_catchment_hydraulic.xmdf''' and '''TC02_001_receiving_HD.nc''' (hold Ctrl to select multiple).
[[File: image of summary with arrows pointing to devices and pollutants]]<br>
* Output File: Click '...', and navigate to the '''TUFLOWCatch\results''' folder. Save the output file as '''TC02_001.tuflow.json'''.
<br>
* res_to_res.exe: Click '...', and navigate to the '''TUFLOW_CATCH_Tutorial_Models\exe\res_to_res.2024-02-AA''' folder. Select '''res_to_res_w64.exe'''.
<li> bufferStrip1 has no paddocks near it, and therefore has no pathogen masses entering or being removed.
<li> Click 'Run'. Once the tool has finished, click 'Close'.
<li> If the removed mass is divided by the cumulative mass, the resulting value represents either the removal constant (if a constant removal equation was used), or the average removal performance (if a table removal method was used). For example, in trench1, the removal performance for SED_CLAY is calculated by: rem SED_CLAY [g] / cum SED_CLAY [g] = 0.4. This matches the removal constant defined in the .tcc. In contrast, bufferStrip1 uses a table removal method for SED_CLAY, resulting in: rem SED_CLAY [g] / cum SED_CLAY [g] = 0.999. This shows that bufferStrip1 removed significantly more clay than trench1. The graph below demonstrates this calculation for each pollutant across all the treatment devices: <br>
<li> In Windows File Explorer, navigate to the '''TUFLOWCatch\results''' folder and drag and drop '''TC02_001.tuflow.json''' into QGIS.
<br>
<li> This will open up a 'Temporal Controller' dock. Hit F7, to open the 'Layer Styling' panel. The Temporal Controller dock and the Layer Styling panel will be used to review the simulation outputs.
[[File: image as described above. eg in onenote]]<br>
<br>
<li><font color=red>other things to show?</font>
</ol>

==TUFLOW CATCH Map Outputs ==
Review the TUFLOW CATCH map outputs using the JSON file:
<ol>
<li> Open tuflow viewer <font color=red>???</font>
<li>In the Layer Styling panel, select 'Conc WQ_PATH_ECOLI_ALICE_100ML' as the result type. Update the symbology as needed.
<li>In the Temporal Controller dock, use the time slider to view the pathogen concentration results. Notice how the ecoli is removed by the treatment devices. In areas where there are no interventions, the pollutant concentrations are much higher (i.e. the eastern waterhole).
<br>
<br>
{{Video|name=}}<br>
{{Video|name=}}<br>
</ol>
</ol>


Use the TUFLOW Viewer to review the TUFLOW HPC map outputs:
==TUFLOW CATCH Map Outputs==
Review the TUFLOW CATCH outputs using the JSON file:
<ol>
<ol>
<li>Open TUFLOW Viewer from the TUFLOW Plugin toolbar and open the simulation results. Select File > Load Results - Map Outputs. Navigate to the '''TUFLOWCatch\results''' folder and select '''TC02_001_catchment_hydraulic.xmdf'''.
<li> In the Layer Styling panel, go to the 'Datasets' tab. There is a list of all available output types. Select 'Depth'.
<li> Go to the 'Contours' tab. Update the 'Depth' symbology as needed.
<li>In the TUFLOW Viewer panel, select 'Conc SED_CLAY'. For consistency, the same symbology as the JSON has been applied in the video below.
<li>Zoom in to bufferStrip1. Use the Plot Time Series tool (from Map Multi) to place a point on either side of the device to see how bufferStrip1 is removing the sediment.
<li> In the Temporal Controller dock, use the time slider to view the depth results throughout the model simulation.
<br>
<br>
{{Video|name=}}<br>
{{Video|name=}}<br>
<li>Using the same process as above, observe the mass removal occurring at the other devices.
<li> In the Datasets tab, select 'Velocity' - both the contours [[File: image of contour button]] and the vectors [[File: image of vector button]].
<li> In the Vectors tab, set 'Arrow Length' to 'Scaled to Magnitude'.
<li> Use the time slider to observe the water flowing from the catchment area into the TUFLOW FV model domain.
<li> <font color=red> show water flowing through culvert??</font>
<br>
<br>
{{Video|name=}}<br>
{{Video|name=}}<br>
Line 40: Line 47:
|uplink=[[TUFLOW_CATCH_Tutorial_M02#Check_Files_and_Results_Output| Back to TUFLOW CATCH Tutorial 2]]
|uplink=[[TUFLOW_CATCH_Tutorial_M02#Check_Files_and_Results_Output| Back to TUFLOW CATCH Tutorial 2]]
}}
}}
<br>

Revision as of 14:47, 8 May 2025

Page Under Construction

Introduction

Review the TUFLOW CATCH interventions output summary. Review how the treatment devices are removing pollutants.

Refer to TUFLOW CATCH Tutorial 1 for information on timeseries outputs.

TUFLOW CATCH Interventions Output Summary

Review the interventions summary:

  1. In Windows File Explorer, navigate to the TUFLOWCatch\results folder and open TC02_001_catchment_hydraulic_intervention_summary.csv.
  2. This file contains final cumulative flows, masses entering and masses removed for all intervention devices and pollutants. All output masses are in grams.

    File:Image of summary with arrows pointing to devices and pollutants

  3. bufferStrip1 has no paddocks near it, and therefore has no pathogen masses entering or being removed.
  4. If the removed mass is divided by the cumulative mass, the resulting value represents either the removal constant (if a constant removal equation was used), or the average removal performance (if a table removal method was used). For example, in trench1, the removal performance for SED_CLAY is calculated by: rem SED_CLAY [g] / cum SED_CLAY [g] = 0.4. This matches the removal constant defined in the .tcc. In contrast, bufferStrip1 uses a table removal method for SED_CLAY, resulting in: rem SED_CLAY [g] / cum SED_CLAY [g] = 0.999. This shows that bufferStrip1 removed significantly more clay than trench1. The graph below demonstrates this calculation for each pollutant across all the treatment devices:

    File:Image as described above. eg in onenote

  5. other things to show?

TUFLOW CATCH Map Outputs

Review the TUFLOW CATCH map outputs using the JSON file:

  1. Open tuflow viewer ???
  2. In the Layer Styling panel, select 'Conc WQ_PATH_ECOLI_ALICE_100ML' as the result type. Update the symbology as needed.
  3. In the Temporal Controller dock, use the time slider to view the pathogen concentration results. Notice how the ecoli is removed by the treatment devices. In areas where there are no interventions, the pollutant concentrations are much higher (i.e. the eastern waterhole).


Use the TUFLOW Viewer to review the TUFLOW HPC map outputs:

  1. Open TUFLOW Viewer from the TUFLOW Plugin toolbar and open the simulation results. Select File > Load Results - Map Outputs. Navigate to the TUFLOWCatch\results folder and select TC02_001_catchment_hydraulic.xmdf.
  2. In the TUFLOW Viewer panel, select 'Conc SED_CLAY'. For consistency, the same symbology as the JSON has been applied in the video below.
  3. Zoom in to bufferStrip1. Use the Plot Time Series tool (from Map Multi) to place a point on either side of the device to see how bufferStrip1 is removing the sediment.


  4. Using the same process as above, observe the mass removal occurring at the other devices.



Up
Back to TUFLOW CATCH Tutorial 2