TUFLOW Message 2194: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
Steph.dufour (talk | contribs) No edit summary |
||
| Line 4: | Line 4: | ||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc=Column 1 values not ascending in a boundary condition table. Table data is output to the .tlf file and console. For a Head-Time the first column is the time data, time values should be unique and in ascending order. The same applies to all boundary condition types. For a HQ (stage-discharge, or rating curve) the height values should be increasing. |
|message_desc=Column 1 values not ascending in a boundary condition table. Table data is output to the .tlf file and console. For a Head-Time the first column is the time data, time values should be unique and in ascending order. The same applies to all boundary condition types. For a HQ (stage-discharge, or rating curve) the height values should be increasing. |
||
|suggestions=Check data, remove duplicate values and sort by first column. |
|suggestions=Check data, remove duplicate values and sort by first column. Note for TUFLOW build 2012-05-AC, consecutive flow values in automatic 2D HQ boundary tables are now automatically removed. |
||
|discussion_page=* [[Talk:TUFLOW Message 2194|Discuss Message 2194]] |
|discussion_page=* [[Talk:TUFLOW Message 2194|Discuss Message 2194]] |
||
|link3='' |
|link3='' |
||
Revision as of 17:38, 22 September 2014
TUFLOW Message
ERROR 2194 - Column 1 values not ascending in ",a," table
Alternate Message
ERROR 2194 - Column 1 values not ascending in ",a," table.
Message Type
ERROR
Description
Column 1 values not ascending in a boundary condition table. Table data is output to the .tlf file and console. For a Head-Time the first column is the time data, time values should be unique and in ascending order. The same applies to all boundary condition types. For a HQ (stage-discharge, or rating curve) the height values should be increasing.
Suggestions
Check data, remove duplicate values and sort by first column. Note for TUFLOW build 2012-05-AC, consecutive flow values in automatic 2D HQ boundary tables are now automatically removed.
| Up |
|---|