Line 27:
==Grid Setup and Cell Size==
A series of north-south oriented (10, 15 and 30m resolution) fixed grid domains
When conceptualising the model domain, a fully 2D solution is preferable over a 1D/2D linked representation provided the 2D resolution of the primary flowpath/s is sufficiently fine. 'Sufficiently fine' is somewhat loosey defined as representing the channel with at minimum 4 fixed grid cells. Here, the 30m fixed grid resolution was determined sufficiently detailed to represent the river bathymetry.
| |||