=1D-2D Configuration=
Connecting a pump from a 1d network to the 2d domain or vice versa is similar to the configuration above, the only difference is that the connection with a 1d structure does not require a 2d SX connection or 1d nwke ‘Node’. A storage chamber in the 1d network can also be modelled using a 1d_na node with an elevation vs area .csv assigned to the node. <br>
The check files are separated into 2D and 1D check files. The output location for these is controlled by commands in the .tcf and .ecf as described above. Not all check file types will be output for all models, if a model has no 2D Z Shape (2d_zsh) format topography modifiers then the _zsh_zpt check file type will not be output by TUFLOW. A list of the check file types is provided below. For more information on each of these please click on the page link.<br>
 
It is also worth noting that the attributes of the check file may also change depending on the features in the model. If a model has soils specified (for infiltration) then the _grd_check file will contain the soil type for each grid cell. If no soils are specified this attribute is not output.<br>
=Estry Control File Setup=
Within the *.ecf the following commands and files are at a minimum required to run a pump with no logically control:<br>