TUFLOW Message 2317: Difference between revisions

Content deleted Content added
No edit summary
No edit summary
Line 2:
|tuflow_message=WARNING 2317 - For direct rainfall models set "Cell Wet/Dry Depth == 0.0002" if CME exceeds 1%.
|alt_msg=NA
'''Note'''- Prior to the 2016 version of TUFLOW, the following messages also could occur:<br>
ERROR 2317 - No points found for XML Surface before "<Faces>".<br>
Due to a clash in numbering this has been renumbered as [[TUFLOW_Message_2517|Message 2517]], please see [[TUFLOW_Message_2517|Message 2517]] for assistance with the XML file error.
|type=[[WARNING]]
|message_desc= The model being simulated contains one or more rainfall boundaries and the cell wet/dry depth is set to a value greater than 0.0002m. The default value as of Build 2006-03-AB, is 0.002m (2mm).