TUFLOW Message 1262

From Tuflow
Revision as of 14:04, 2 February 2011 by tuflow>Par
Jump to navigation Jump to search

TUFLOW Message
WARNING 1262 - Manning's n value of <Manning's n value> for channel <Channel ID> is unusually low or high.

Alternate Message
NA

Message Type
WARNING

Description
Manning's n value assigned to channel is outside normal range.

Suggestions
Check Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process). This can occur if a the multiplication value is set to a typical Manning's value (e.g. 0.04) and materials are defined in the XZM cross-section. In this case the Manning's n value may become 0.04 x 0.04 = 0.0016!


Up
Go-up.png 1xxx Messages