TUFLOW Message 2194
Revision as of 17:38, 22 September 2014 by Steph.dufour (talk | contribs)
TUFLOW Message
ERROR 2194 - Column 1 values not ascending in ",a," table
Alternate Message
ERROR 2194 - Column 1 values not ascending in ",a," table.
Message Type
ERROR
Description
Column 1 values not ascending in a boundary condition table. Table data is output to the .tlf file and console. For a Head-Time the first column is the time data, time values should be unique and in ascending order. The same applies to all boundary condition types. For a HQ (stage-discharge, or rating curve) the height values should be increasing.
Suggestions
Check data, remove duplicate values and sort by first column. Note for TUFLOW build 2012-05-AC, consecutive flow values in automatic 2D HQ boundary tables are now automatically removed.
Up |
---|