WIBU Configure Network Client

From Tuflow
Jump to navigation Jump to search

Introduction

This page contains instructions for configuring a client computer to access a network TUFLOW licence. This requires that you have:

Method

  1. Open the CodeMeter Control Center via the start menu:
    CodeMeter Start.png

  2. Open the WebAdmin via the button in the lower right.
  3. CodeMeter ControlCentre.png

  4. In CodeMeter WebAdmin navigate to the Configuration >> Basic >> Sever Search List tab and enter the server name or IP address in the Server Search list. Click Add to include the server IP to the list.

  5. CodeMeter WebAdmin.png

    Click Apply to make the changes.
  6. The client machine should now be configured to access the network TUFLOW dongle. This can be tested on the server by double clicking the TUFLOW Executable (for example TUFLOW_iSP_w64.exe). A DOS window should open which lists the licence information (licence types and numbers will be different to the example shown below).
    TUFLOW DOS Test1.JPG


Troubleshooting

If your licences are not listed in the DOS window when you test whether the connection to the server has been successful, consider the following:

Check Server Connectivity

A easy way to check for connectivity between the client computer and the licence server is to ping the server from the client machine. This can be done by:

  1. Open a command prompt on the client computer (Start >> Run and then type in cmd or simpy type cmd into the search option in the start menu
  2. Enter the command ping <server> where <server> is the IP address or server name as entered into the CodeMeter server search list. For example:
    ping 192.168.1.1
    ping TUFLOW_server
    If successful the output will show that a reply is received as per the image below.
    CM ping server.jpg

    If no reply is received, there appears to be a connectivity or firewall issue preventing access between the client and the server. Resolving this should hopefully allow the client computer to access the TUFLOW server.

Check AV and Port Blocking

If the above steps have been performed and the client computer is still unable to access the network licence, the most likely reason is that there is anti-virus or a firewall blocking access. By default the Codemeter software uses port 22350 for communication. This can be changed in the Configuration >> Server tab in CodeMeter webadmin. Temporarily disabling any antivirus on the computers could be used to confirm if this is causing the communication issue, if so, an exception would need to be added to your AV software.

Other

If you are unable to get TUFLOW connecting to a network licence server please contact support@tuflow.com.

Up
Go-up.png Return to WIBU Licensing Main Page