TUFLOW Message 1298
Revision as of 15:34, 5 July 2022 by Melissa.Moghanloo (talk | contribs)
TUFLOW Message
WARNING 1298 - 1D timestep must be less than or equal to smallest timestep from the 2D domains
Alternate Message
NA
Message Type
WARNING
Description
1D timestep must be must be less than or equal to the timestep of the 2D model. If multiple 2D domains are used the 1D timestep must be less than or equal to the smallest timestep in any of the 2D domains. If using a 1D timestep smaller than 2D timestep, the 2D timestep needs to be divisible by the 1D timestep. For example a with a 2D timestep of 4 seconds a 1D timestep of 1 or 2 seconds is ok, but 2.5 not valid.
Suggestions
Specify a 1D timestep less than or equal to the 2D timestep or the smallest 2D timestep for a multiple 2D domain model.
Up |
---|
1xxx Messages |