TUFLOW Message 1470
TUFLOW Message
WARNING 1470 - Neither Gate Speed nor Period Opening/Closing is specified. Assuming Period Opening/Closing of 60 sec for XXX Control: <control_name>
Alternate Message
CHECK 1470 - Both Gate Speed nor Period Opening/Closing is specified. Assuming Period Opening/Closing of 60 sec for XXX Control: <control_name>
Message Type
ERROR
Description
Both Gate Speed and Period Opening/Closing commands can define operational speed of gated structures.
- if neither command is specified the default Period Opening/Closing of 60 sec is used to set the Gate Speed
- if both command are specified Period Opening/Closing is ignored and Gate Speed is used
Same rule applies to the Weir Height/Width Speed commands for operational weirs.
Suggestions
Check toc file input to ensure the operational control works as intended.