Revision as of 16:18, 26 March 2026 by ShuangGao (talk | contribs) (Created page with "{{TUFLOW_Message |tuflow_message=WARNING 1470 - Neither Gate Speed nor Period Opening/Closing is specified. Assuming Period Opening/Closing of 60 sec for XXX Control: <control_name> |alt_msg=CHECK 1470 - Both Gate Speed nor Period Opening/Closing is specified. Assuming Period Opening/Closing of 60 sec for XXX Control: <control_name> |type=ERROR |message_desc=Both <tt><font color="blue">Gate Speed</font> and <tt><font color="blue">Period Opening/Closing</font> comman...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

TUFLOW Message
WARNING 1470 - Neither Gate Speed nor Period Opening/Closing is specified. Assuming Period Opening/Closing of 60 sec for XXX Control: <control_name>

Alternate Message
CHECK 1470 - Both Gate Speed nor Period Opening/Closing is specified. Assuming Period Opening/Closing of 60 sec for XXX Control: <control_name>

Message Type
ERROR

Description
Both Gate Speed and Period Opening/Closing commands can define operational speed of gated structures.

  • if neither command is specified the default Period Opening/Closing of 60 sec is used to set the Gate Speed
  • if both command are specified Period Opening/Closing is ignored and Gate Speed is used

Same rule applies to the Weir Height/Width Speed commands for operational weirs.

Suggestions
Check toc file input to ensure the operational control works as intended.